Electrolux 30" Coil Elements Installation Instructions Manual

Electric cooktop
Table of Contents
Available languages

Available languages

Quick Links

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in
WARNING
the vicinity of this or any other appliance.
• All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only
electrical supply with ground.
• Please note minimum distances between cooktop and overhead cabinets is 30" (76.2 cm).
Cooktop Dimensions
Cooktop Cutout Dimensions
MODEL
30" Coil Elements
36" Coil Elements
MODEL
30" Coil Elements
36" Coil Elements
All dimensions are in inches (cm).
* Allow 2" (5.1 cm) space below cooktop to clear the electric cable and allow for
installation of the junction box on the wall at the back of the cooktop.
Printed in United States
IMPORTANT INSTALLATION-INFORMATION
30" Min*
(76.2 cm)
A
E
G
PRODUCT DIMENSIONS
A. LENGTH
B. WIDTH
30 (76.2)
21¾ (55.2)
36 (91.4)
21¾ (55.2)
CUT OUT DIMENSIONS
F. LENGTH
MINIMUM
MAXIMUM
27¼ (69.2)
28½ (72.4)
33
7
/
(86)
34¼ (87)
8
* 30" (76.2 cm) min. for unprotected cabinet
24" (61 cm) min. for protected surface
B
C
D
H
Figure 1
C. DEPTH
4½ (11.4)
4½ (11.4)
G. WIDTH
MINIMUM
19
1
/
(48.6)
8
19
1
/
(48.6)
8
1
2½" (6.4 cm)
F
D. BOX LENGTH
E. BOX WIDTH
27 (68.6)
19 (48.3)
33¼ (84.5)
19 (48.3)
H. DEPTH BELOW
MAXIMUM
COOKTOP*
19¾ (50.2)
7 (17.8)
19¾ (50.2)
7 (17.8)
P/N 318201423 (0506) Rev. A
English – pages 1-6
Español – pages 7-12
Table of Contents
loading

Summary of Contents for Electrolux 30" Coil Elements

  • Page 1 ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in WARNING the vicinity of this or any other appliance.
  • Page 2 ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Overhead Cabinet Should Not Exceed a Maximum Depth of 13" (33 cm) Min. Min. Recommended 30" (76.2 cm) Min. Clearance Distance Between Rear Between the Top of the Edge of Cutout and Cooking Platform and the Nearest Combustible Bottom of an Unprotected 10"...
  • Page 3: Important Safety Instructions

    ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS NOTE: Wire sizes and connections must conform with Important Notes to the Installer the fuse size and rating of the appliance in accordance 1. Read all instructions contained in these installation with the National Electrical Code ANSI/NFPA No. 70– instructions before installing the cooktop.
  • Page 4 ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Where local codes permit connecting the appliance- Where local codes DO NOT permit connecting the grounding conductor to the neutral (white) wire appliance-grounding conductor to the neutral (see figure 3): (white) wire, or if connecting to 4-wire electrical The 3-conductor cord or cable must be replaced with a 4- system (see figure 4): conductor cord or cable where local codes prohibit grounding...
  • Page 5: Cooktop Installation

    ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Cooktop Installation Checking Operation These cooktops are designed to fit various cutout sizes. Refer to the Use and Care Guide for operation. The minimum and maximum cutout openings are shown in Figure 1. Do not touch cooktop glass or elements. CAUTION They may be hot enough to burn you.
  • Page 6 ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Notes...
  • Page 7 INSTRUCCIONES PARA LA INSTALACION DE LA ESTUFA ELECTRICA LA INSTALACION Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO. IMPORTANTE: GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE ELECTRICIDAD. LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA. PARA SU SEGURIDAD: No almanece ni utilice gasolina u otros vapores y líquidos inflamables en la proximidad de este o de cualquier otro artefacto.
  • Page 8 INSTRUCCIONES PARA LA INSTALACION DE LA ESTUFA ELECTRICA El armario superior no debe sobrepasar una profundidad máxima de 13" (33 cm) Min. min. distancia recomendada entre el 30" (76.2 cm) min. de espacio borde trasero del corte y entre la parte superior del fogón y el compartimiento de la parte inferior de un armario de 10"...
  • Page 9: Instrucciones Importantes De Seguridad

    INSTRUCCIONES PARA LA INSTALACION DE LA ESTUFA ELECTRICA NOTA: El tamaño de los cables y de las conexiones debe Notas importantes para el instalador de estar en conformidad con el tamaño del fusible y con la 1. Lea todas las instrucciones contenidas en este manual capacidad del electrodomestico y de acuerdo con el Código antes de instalar la estufa.
  • Page 10 INSTRUCCIONES PARA LA INSTALACION DE LA ESTUFA ELECTRICA Donde los códigos locales permitan conectar el Donde los códigos locales NO permitan conectar el conductor de puesta a tierra del eléctrodoméstico al conductor de puesta a tierra del eléctrodoméstico al neutral (blanco) (vea figura 3): neutral (blanco), o si está...
  • Page 11: Instalación De La Estufa

    INSTRUCCIONES PARA LA INSTALACION DE LA ESTUFA ELECTRICA Instalación de la estufa Revisión de operación Si la plancha de cocinar va a ser usada en una Consulte el Manual del Usuario para las instrucciones de instalación nueva, use las dimensiones mínimas que se funcionamiento.
  • Page 12 INSTRUCCIONES PARA LA INSTALACION DE LA ESTUFA ELECTRICA Notas...

Table of Contents