Changing The Blade; Adjusting Blade Parallel/Miter Gage Slots - Black & Decker FS210LS FireStorm Instruction Manual

10" table saw
Hide thumbs Also See for FS210LS FireStorm:
Table of Contents
Available languages

Available languages

ADJUSTING BLADE PARALLEL TO
MITER GAGE SLOTS
The blade was adjusted parallel to the miter gage slots
at the factory. In order to insure accurate cuts and help
prevent kickback when cutting, this adjustment should
be rechecked and if necessary, readjusted as follows:
1. DISCONNECT MACHINE FROM POWER SOURCE.
2. Raise the blade to its highest position and adjust the
blade so it is 90 degrees to the table.
3. Select a tooth on the saw blade that is set to the left.
Mark this tooth with a pencil or marker.
4. Using a combination square, place the body (A)
Fig. 41, of the square against the miter gage slot and
adjust the blade (B) of the square until it just touches the
marked tooth, as shown.
5. Rotate the blade and check the same marked blade
tooth at the rear of the saw table in the same manner, as
shown in Fig. 42.
6. If the front and back measurements (Figs. 41 and 42)
are not identical, you can adjust the blade. Start by
loosening the nuts below the four screws (C) Fig. 43 on
the table. Then loosen the screws (C). Carefully move
the saw blade until the blade is parallel to the miter
gauge slot. When done, tighten four nuts under the table
and the four screws (C) Fig. 43 securely.
NOTE: If sufficient adjustment cannot be achieved by
loosening screws (C), screws (D) may also be loosened
if absolutely necessary to make the adjustment.
NOTE: Guard has been removed for illustrative
purposes only.

CHANGING THE BLADE

DISCONNECT MACHINE FROM POWER
SOURCE. USE ONLY 10" DIAMETER
SAW BLADES RATED FOR 5000 RPM OR HIGHER
WITH 5/8" ARBOR HOLES.
1. Raise the saw blade to its maximum height and
remove the table insert (A) Fig. 44.
2. Using the open end wrench (B) Fig. 44, place open
end of wrench on flats on inside blade flange to keep the
saw arbor from rotating and remove arbor nut (C) with
wrench (D). Turn nut (C) counterclockwise to remove.
Remove outside blade flange (E) and saw blade (F).
3. Assemble new blade, making certain teeth of blade
are pointing down at the front of the saw table and
assemble the outside blade flange (E) Fig. 44, and arbor
nut (C). Tighten nut (C) with wrench (D) by turning nut
clockwise while holding arbor steady with other wrench
(B).
4. Replace table insert.
C
D
A
21
A
B
Fig. 41
Fig. 42
C
D
Fig. 43
B
C
E
F
Fig. 44
Table of Contents