Summary of Contents for Electrolux CARAVAN AES II RM 6505

  • Page 1 MANUAL CARAVAN RA/RM-2D AES II 0402 RM 6505 Deutsch Seite English page Nederlands pag. Italiano pagina Français page 822 70 79-05...
  • Page 3: Table Of Contents

    OPERATING AND INSTALLATION INSTRUCTIONS FOR ELECTROLUX REFRIGERATORS INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator OPERATING INSTRUCTIONS ......13 and hope you will derive much satisfaction from using it, CONTROLS ........... 13 but first a few well-meant words of advice: STARTING THE REFRIGERATOR ....
  • Page 4: Operating Instructions

    be allowed to escape by briefly turning on the refrigerator OPERATING INSTRUCTIONS or other appliances. This will ensure that the flame lights CONTROLS immediately. If the flame goes out (by gust of wind etc.), the igniter is immediately activated and reignites the gas. Note: The control electronics and the igniter must have 12 V DC supply to operate.
  • Page 5: Travel Catch

    Check the formation of frost regularly by snow, leaves etc. every week and when it gets about 3 mm thick, defrost ELECTROLUX ventilation grilles model L500, can be the refrigerator. fitted with winter covers, model WA130, to protect the To defrost the refrigerator, turn it off and remove the ice cooling unit against cold air.
  • Page 6: If The Refrigerator Fails To Work

    AES LED (C) flashes red: see chapter Gas A special door reversing kit must be used to reverse the trouble-shooting. doors. For further information, contact your dealer or Electrolux. If the refrigerator is not cold enough it may be because: DOOR PANEL...
  • Page 7: Installation/Building-In

    We recommend fitting 2 side vents, model L500, wiring etc. alternative one L500 and one roof vent model R500, which are specially developed by Electrolux for this purpose. The L500-ventilation grilles permit inspection and small repairs to be carried out without the necessity to remove...
  • Page 8: Lp Gas Connection

    VENTILATION OF THE UNIT Sealing gasket e.g. of V-type This piece is Cut out opening for the already on the roof vent R500 refrigerator is 87 x 507 mm Cut out opening for the Condenser side vent L500 Condenser is 341 x 451 mm. L205 is 156 x 451 mm.
  • Page 9: Electrical Connection

    the wire which is coloured Brown must be connected CAUTION! CHECK THAT THE GAS SUPPLIED to the terminal which is marked with the letter L or TO THE REFRIGERATOR IS AT THE CORRECT coloured Red. PRESSURE. SEE THE REDUCING VALVE ON THE LP GAS CONTAINER.
  • Page 10: Technical Data

    Cross-sections TECHNICAL DATA RM 6505 The D+ (alternator) is a signal cable and therefore 1-1.5 Overall dimensions, refrigerator is sufficient. Height (incl. controls) ....1245 mm Connection to 12 V + and - must be done with a 10 mm Width ..........