Summary of Contents for Prizer Hoods CHIMNEY STYLE HOODS

  • Page 2: Table Of Contents

    SAFETY PROCEDURES PRECAUTIONS FOR RECEIVING AND STORING HOOD INSTALLATION PLANNING INSTALLING CHIMNEY STYLE HOODS ROUGH-IN DIMENSIONS FOR CHIMNEY STYLE HOODS INSTALLING CHIMNEY STYLE HOODS (CONTINUED) AN ALTERNATE INSTALLATION FOR A CHIMNEY STYLE HOOD INSTALLING A CHIMNEY STYLE HOOD WITH A REAR DISCHARGE THROUGH THE DUCT COVER INSTALLING A CFM600 FAN IN A 30"...
  • Page 3: Important Safety Instructions

    Boilovers cause smoke and greasy other metal tray. Immediately manufacturer - Prizer Hoods. spillovers may ignite. Heat oils turn the gas burner OFF. slowly on low or medium Before servicing or cleaning the settings.
  • Page 4: Safety Procedures

    SAFETY PROCEDURES FOR INSTALLING YOUR NEW PRIZER HOOD (continued) CAUTION - TO REDUCE THE guidelines and safety standards NEVER place a control switch such as those published by the where it can be reached from a RISK FIRE, ELECTRIC National Fire Protection tub or shower.
  • Page 5: Installation Planning

    • Please read the instructions in their entirety prior to installing the hood. CHIMNEY STYLE HOODS INCLUDE AN INSTALLATION PACKAGE WITH THE FOLLOWING COMPONENT PARTS: • Ten 10-24 Nuts • Ten #10 Self-Tapping Screws - 2” long •...
  • Page 6: Installing Chimney Style Hoods

    INSTALLING CHIMNEY STYLE HOODS Duct Cover use), separate the transition from the hood base and duct cover. Install the transition to the duct work ensuring the Transition transition. Verify that the transition is ush, and centered to the bottom of the Duct Cover. When transition Plate is not hindered from opening if using mechanical fasteners.
  • Page 7: Rough-In Dimensions For Chimney Style Hoods

    ROUGH-IN DIMENSIONS FOR CHIMNEY STYLE HOODS Electrical and Ductwork Electrical and Ductwork Rough-In location Rough-In location Top View Front View 10" Transition with Damper (36-66" Hood) 8" Transition with Damper (30" Hood) 6" Electrical Knockout Location 18" (Rear Electrical Rough-In Location) 9-1/4"...
  • Page 8: Installing Chimney Style Hoods (Continued)

    INSTALLING CHIMNEY STYLE HOODS - (continued) Supply Ductwork volt) (see Figure 2. - Page 4). If using a remote fan please see section “Wiring a Remote Fan”. (see Page 11) If using an in-hood CFM1200 or CFM600 fan, slide the...
  • Page 9: An Alternate Installation For A Chimney Style Hood

    AN ALTERNATE INSTALLATION FOR A CHIMNEY STYLE HOOD In certain situations the installer may opt for a di erent installation sequence. e alternate sequence is listed below. Alternate Installation Supply Ductwork opening in top of structure, if available. (see Figure 7. - Page 6) Install Transition to ductwork, ensuring transition bottom transition to ductwork.
  • Page 10: Installing A Chimney Style Hood With Arear Discharge Through The Duct Cover

    INSTALLING A CHIMNEY STYLE HOOD WITH A REAR DISCHARGE THROUGH DUCT COVER e Chimney Style Hood can adapt to a rear discharge application but with the following limitations: A rear discharge application only works when using a 24" tall duct cover or taller. e 12"...
  • Page 11: Installing A Cfm600 Fan In A 30" Wide Chimney Style Hood

    INSTALLING A CFM600 FAN IN A 30” WIDE CHIMNEY STYLE HOOD ese instructions are only applicable when installing a CFM600 fan in a 30" wide chimney style hood. e Prizer 30" wide chimney style hood has an adapter plate installed inside the hood. In order to install a CFM600 fan within a 30"...
  • Page 12: Wiring A Remote Fan

    WIRING A REMOTE FAN When using a remote fan with a chimney style hood, follow the instructions noted below. NOTE: e chimney style hood is designed to accept a 3-speed fan motor only. It not designed to accept a variable speed fan! e molex plug mounted within the front portion of the hood supplies power to the remote fan.
  • Page 13: Wiring Diagram For Chimney Style Hoods

    WIRING DIAGRAM FOR CHIMNEY STYLE HOODS...
  • Page 14: Cfm600 Fan - Chimney / Island Application - 8" Transition

    CFM 600 IN-HOOD FAN CHIMNEY AND ISLAND APPLICATION - 8” TRANSITION EXCEPTION: - MANHATTAN WALL 36” WIDE - MANHATTAN WALL 42“ WIDE - MANHATTAN ISLAND 36” WIDE - MANHATTAN ISLAND 42” WIDE THE ABOVE MUST BE USED WITH AN 8” ROUND COLLAR WITH BACKDRAFT DAMPER CFM600 Fan Maximum CFM: 600...
  • Page 15: Cfm1200 Fan - Chimney / Island Application - 10" Transition

    CFM 1200 IN-HOOD FAN CHIMNEY AND ISLAND APPLICATION - 10” TRANSITION EXCEPTION: - MANHATTAN WALL 36” WIDE - MANHATTAN WALL 42“ WIDE - MANHATTAN ISLAND 36” WIDE - MANHATTAN ISLAND 42” WIDE THE ABOVE MUST BE USED WITH AN 8” ROUND COLLAR WITH BACKDRAFT DAMPER CFM1200 FAN Maximum CFM: 1200...
  • Page 16: Hood Features

    HOOD FEATURES Model Lighting Filters Available Widths Depth Height Halogen & NUMBER OF FILTERS PER WIDTH WALL HOODS Heat Halogen 2 THIN BAFFLES LP 30” - 42” 30” 36” 42” 48” 54” 60” 66” 22” 18” Halogen 3 THIN BAFFLES LP 48”...
  • Page 17: Baffle Filters - Grease Troughs - Halogen Lights

    To water using laundry detergent without fabric softeners and purchase halogen bulbs through Prizer Hoods, you may place in dryer without fabric softening sheets. contact our Customer Service Department or visit your...
  • Page 18: Cleaning Recommendations

    “Clean Source” and “Brite Boy” cleaner may be purchased directly from Prizer Hoods.
  • Page 19: Trouble-Shooting Tips

    Prizer Hoods reserves the right to change speci cations or design without notice. Some models are certi ed for use in Canada. Prizer Hoods is not responsible for products which are transported from the United States for use in Canada.