(11) Turn the ADF unit upside down.
(12) Remove the three Taptite cup S 3x12 screws to remove the Hinge ASSY L from the ADF
unit.
Harness routing: Refer to
8.15 Hinge R/Hinge R Support
(1) Remove the Taitite cup B 3x10 screw to remove the Hinge R support and Hinge R from
the ADF unit.
Hinge R support
Taitite cup B 3x10
Taptite cup S 3x12
Fig. 3-44
"
ADF
Unit",
Fig. 3-45
3-52
Hinge ASSY L
Taptite cup S 3x12
"
Document Scanner Unit"
Hinge R
ADF unit
ADF unit