Honeywell LYNX Touch Series Installation And Setup Manual

Honeywell LYNX Touch Series Installation And Setup Manual

Hide thumbs Also See for LYNX Touch Series:
Table of Contents
LYNX Touch Series
Security Systems
Installation and Setup Guide
800-10614V1 12/12 Rev. A
Table of Contents
loading

Summary of Contents for Honeywell LYNX Touch Series

  • Page 1 LYNX Touch Series Security Systems Installation and Setup Guide 800-10614V1 12/12 Rev. A...
  • Page 2: Recommendations For Proper Protection

    LYNX Touch Installation and Setup Guide RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper Coverage for the Protected Premises. Recommendations for Smoke and Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below.
  • Page 3: Table Of Contents

    LYNX Touch Installation and Setup Guide Table of Contents System Features ..................................5 Features ...................................... 5 Mounting the Control ................................6 Wall Mounting .................................... 6 Desktop Mounting ..................................6 Wiring Overview ..................................6 Wiring Connections ................................7 Installing the L5000-RJ-31X in the LYNX Touch Control ....................8 AC Power and Backup Battery ............................
  • Page 4 LYNX Touch Installation and Setup Guide Table of Contents (Continued) GSM Information ................................43 Communications ID Numbers ............................44 Test Communications ................................ 44 Setup Communications ..............................44 Registering the LYNX Touch ............................44 Register through AlarmNet Direct Website ........................45 Register by Phone ................................
  • Page 5: System Features

    Control Z-Wave Home Automation devices (requires IBM-compatible computer using Compass installation of a Communications Module). Control up downloader software and specified HAYES or Honeywell CIA modem or via capable GSM, IP or - 3 thermostats WiFi communications module - 4 door locks •...
  • Page 6: Mounting The Control

    LYNX Touch Installation and Setup Guide Mounting the Control Wall Mounting MOUNTING TIE WRAP HOOKS (HINGES) POINT (3) INSTALL SCREW IN CASE TAMPER BACK Release the front case from the back case by CASE depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver.
  • Page 7: Wiring Connections

    LYNX Touch Installation and Setup Guide Wiring Connections INCOMING Make Earth Ground Connection - The designated earth ground PHONE LINE terminal EGND must be terminated in a good earth ground for the lightning transient protective devices in this product to be effective. RING The following are examples of good earth grounds available at most installations:...
  • Page 8: Installing The L5000-Rj31X In The Lynx Touch Control

    LYNX Touch Installation and Setup Guide Wiring Connections Installing the L5000-RJ31X in the LYNX Touch Control An auxiliary L5000-RJ31X receptacle can be installed in the LYNX Touch that will allow the telephone cable to be disconnected without requiring the unit to be opened up. Using a wire cutter or knife cut the plastic tabs that secure the receptacle knockout from the left side of the LYNX Touch back case.
  • Page 9: Ac Power And Backup Battery

    LYNX Touch Installation and Setup Guide AC Power and Backup Battery The system is powered by a 9 Volt DC, 2.7 Amp Plug-in Power Supply, 300-04705 or 300-04065 (300-04063 in Canada). Refer to the wiring table below for wire gauge and length. In the event of an AC power loss, the system is supported by a long life backup battery that is supervised for connection and for low voltage conditions.
  • Page 10: Installing/Configuring Communications & Home Automation Modules

    LYNX Touch Installation and Setup Guide Installing/Configuring Communication & Home Automation Modules General This LYNX Touch control supports central station reporting using wireless (GSM) and hardwire (IP) communications modules. It also supports upload/download programming capability via the Internet or a Private local area network (Intranet).
  • Page 11: Installing The Ilp5

    LYNX Touch Installation and Setup Guide Installing/Configuring Communication & Home Automation Modules Installing the ILP5 Ethernet Communications Module Do not install the ILP5 if the L5100-WiFi communications module is being installed. Ensure that the connector board and cable are securely installed in the ILP5 before installing the communications module in the LYNX Touch.
  • Page 12: Installing The L5100-Wifi Module

    LYNX Touch Installation and Setup Guide Installing/Configuring Communication & Home Automation Modules Do not install the L5100-WiFi if the ILP5 Ethernet communications module is being installed. Installing the L5100-WiFi module Install the L5100-WiFi into the LYNX Touch control front case as shown below. Ensure that the receptacle is properly seated into the edge connector on the right (speaker) side of the control’s circuit board.
  • Page 13: Installing Wireless Zones

    LYNX Touch Installation and Setup Guide Installing Wireless Zones General Information Zones The control supports up to 63 total wireless zones using 5800 Series transmitters, and wireless buttons. Range The built-in RF receiver can detect signals from wireless transmitters within a nominal range of 200 feet. Transmitters 5800 Series transmitters have built-in serial numbers that must be entered into the system using the “Zones”...
  • Page 14: Rf Sniffer Mode Test

    LYNX Touch Installation and Setup Guide Installing Wireless Zones RF Sniffer Test Mode This mode is used after all transmitters have been entered to check that all transmitters have been properly programmed. Sniffer mode does not automatically expire. You must manually exit Sniffer mode by selecting Off and entering the Installer Code to return to normal operation.
  • Page 15: 5800 Series Transmitter Loop Numbers

    LYNX Touch Installation and Setup Guide Installing Wireless Zones 5800 Series Transmitter Loop Numbers (Refer to this information when programming transmitters) The following illustration shows the compatible transmitters, their associated input types and loop designations. LOOP 1 LOOP 1 (LOW (LOW SENSITIVITY SENSITIVITY...
  • Page 16: Mechanics Of Programming

    LYNX Touch Installation and Setup Guide Mechanics of Programming Navigating Menus Touch-screen Display LYNX Touch’s Liquid Crystal Display (LCD) touch-screen displays variable icons and text on “screens”. The screen displays status icons and associated text, the current time and date, system status information and menu choices.
  • Page 17: Security Screen Menus

    LYNX Touch Installation and Setup Guide Mechanics of Programming Security Menu Screens System Status is displayed at the top of each screen. The time and date are displayed at the bottom of the Home Screen. The Security Home Screen consists of two pages. The first page displays the system status and eight selection “buttons”...
  • Page 18: General Programming Information

    LYNX Touch Installation and Setup Guide Mechanics of Programming General Programming Information When power cycling the control, remove AC power first and wait approximately 1 minute before disconnecting battery. Programming options are stored in non-removable, electrically erasable, nonvolatile EEROM memory. The system can be programmed at any time, even at the installer's premises prior to the actual installation.
  • Page 19: Loading Factory Defaults

    LYNX Touch Installation and Setup Guide Mechanics of Programming Loading Factory Defaults To load the factory defaults, enter the Installer Programming Mode and advance to second page of the System Programming and refer to following procedure . Refer to the Programming Default Values section of this manual to view the Default Values.
  • Page 20: Zone Response Type Definitions

    LYNX Touch Installation and Setup Guide Zone Response Type Definitions General Information During programming, you must assign a zone type to each zone, which defines the way in which the system responds to faults in that zone. Zone types are defined below. Type Function Characteristics...
  • Page 21 LYNX Touch Installation and Setup Guide Zone Response Type Definitions Type Function Characteristics • Exit delay regardless of the arming mode selected. Arm–Stay Special-purpose zone type used with 5800 Series • System is armed in the STAY mode when the zone is activated. wireless pushbutton units.
  • Page 22: Programming The Control

    LYNX Touch Installation and Setup Guide Programming the Control After entering the System Programming mode select from the options provided on the First and Second Installer Programming tools screens as shown in the accompanying figure. System Programming... System Programming... Sounder System Settings Installer Code System Type...
  • Page 23: System Type

    LYNX Touch Installation and Setup Guide Programming the Control System Type The following system options are programmed in this section: Option Function RF Jam Enable or disable RF Jam Log and Reporting Speaker Phone Enable or disable Speaker Phone mode. (End User feature) Two Way Voice Enable or disable Two Way Voice communication with the Central Station.
  • Page 24 LYNX Touch Installation and Setup Guide Programming the Control Screen ACTION 8. If Keypad or Trouble was selected in Step 7, the “Phone Detect Time” option is Phone Detect Time displayed. Select “Phone Detect Time”. The system scrolls between the following options: 2 Minutes 1 Minute 2 Minutes...
  • Page 25: Program Date And Time

    LYNX Touch Installation and Setup Guide Programming the Control Program Date and Time Note: If applicable, preprogrammed defaults for the LYNX Touch Control are shown on the screen unless otherwise noted. SCREEN ACTION Note: If you are installing a GSMVLP5-4G/GSMVLP5CN4G or ILP5 Date Time Communication Module, the time and date will be programmed and updated automatically via Central Station.
  • Page 26: Program The Communications Module

    LYNX Touch Installation and Setup Guide Programming the Control Program the Communications Module A router is required if you are installing the L5100-WiFi module. The router must be powered on and connected for WiFi operation (alarm reporting) to occur. The following system options are programmed in this section: Option Function Communications Path...
  • Page 27 LYNX Touch Installation and Setup Guide Programming the Control SCREEN ACTION Select “Sub ID”. Enter the 4-digit Subscriber Account Number (Decimal). Sub ID Options 0001-9999 Select “Supervision”. The system scrolls between the following options: Supervision 24 Hours 24 Hours None 30 Days Select “Old Alarm Time”.
  • Page 28: Program The Z-Wave Module

    LYNX Touch Installation and Setup Guide Programming the Control Program the Z-Wave Module The following system options are programmed in this section: Option Function Z-Wave Enables or disables the Z-Wave Module Temperature Display Toggles between Fahrenheit and Celsius (for Z-Wave Theromstat) Notes: 1.
  • Page 29: Program Zones

    For a list of the pre-programmed Zone Descriptors, please visit http://www.security.honeywell.com/hsc/resources/MyWebTech Select “Zone Description 1 or Zone Description 2”. Using the displayed keypad enter Zone Description 1 or Zone Description 2. The system announces the Zone Description. Enter “Done”, when you are finished.
  • Page 30 LYNX Touch Installation and Setup Guide Programming the Control SCREEN ACTION Device Type Device Type Select “Device Type”. The system displays the following options (dependant upon the Device Type selection): Door Window Motion Sensor Glass Break Smoke Detector Heat Sensor Carbon Mono.
  • Page 31: Program Keys

    LYNX Touch Installation and Setup Guide Programming the Control Program Keys The following system options are programmed in this section Option Function Key Type Select the specific type of key being entered or enrolled User Associates the Key with a specific User Serial Number Manually enter key serial number or enroll via RF transmission Zone...
  • Page 32 LYNX Touch Installation and Setup Guide Programming the Control SCREEN ACTION Button Key * Zn * Button Key * - Zn * Select the desired Button Key and enter a function for each button key. The system displays the following options: Disarm Arm Away Arm Stay...
  • Page 33: Program Reporter

    LYNX Touch Installation and Setup Guide Programming the Control Reporter When Compass service is required and GSM or IP are the only reporting channels: As part of Primary Central Station programming; the “Phone Type” must be set to any selection other than “None”, the “Communicator Type” must be set to GSM or IP, as applicable, and must match the compass value;...
  • Page 34 LYNX Touch Installation and Setup Guide Programming the Control Notes: If applicable, preprogrammed defaults for the LYNX Touch Control are shown on the screen unless otherwise noted. When GSM is used as the Primary Communications channel for any Total Connect service, the GSM Radio must be selected as the Primary Reporting Path (Preferred Radio).
  • Page 35 LYNX Touch Installation and Setup Guide Programming the Control SCREEN ACTION Select “Phone Type”. The System displays the following options: Phone Type None None Contact Id: 4 Digit Contact Id: 10 Digit Select “Communicator Type”. The System displays the following options: Communicator Type None None...
  • Page 36 LYNX Touch Installation and Setup Guide Programming the Control SCREEN ACTION Select “Open/Close”. The System toggles between “Disabled” and “Enabled”. Report Open/Close Disabled Select “Report Tests”. The System toggles between “Disabled” and “Enabled”. Report Tests Disabled Select “Follow Me Phone 2” to program the “Follow Me” Reminder telephone number 2. Follow Me Phone 2 Select “Phone Type”.
  • Page 37 LYNX Touch Installation and Setup Guide Programming the Control SCREEN ACTION Select “Trouble”. The System toggles between “Disabled” and “Enabled”. Trouble Enabled Select “Trouble Restore”. The System toggles between “Disabled” and “Enabled”. Trouble Restore Enabled Select “Alarm Restore”. The System toggles between “Disabled” and “Enabled”. Alarm Restore Enabled Select “Alarm Cancel”.
  • Page 38 LYNX Touch Installation and Setup Guide Programming the Control SCREEN ACTION Select “Number of Reports” Number of Reports LYNX Touch 2 Reports The system scrolls between the following options: 1, 2, 3, 4, 5 and 6 Reports LYNX Touch (L5100CN) Canada The system toggles between “Unlimited”...
  • Page 39: Sounder

    LYNX Touch Installation and Setup Guide Programming the Control Sounder The following system options are programmed in this section: Option Function Burglary Alarm Sound Switches the full 110 dB alarm sound for burglary On/Off. Burglary Bell Timeout Select the time for timeout of the Burglary Alarm sounder. Fire Bell Timeout Select the time for timeout of the Fire Alarm sounder.
  • Page 40: System Settings

    LYNX Touch Installation and Setup Guide Programming the Control System Settings The following system options are programmed in this section: Option Function Entry Delay1/Entry Delay 2 Selects an Entry Delay time in seconds. The system will wait the time entered before sounding alarm upon entering if system is not disarmed.
  • Page 41 LYNX Touch Installation and Setup Guide Programming the Control Note: If applicable, preprogrammed defaults for the LYNX Touch Control are shown on the screen unless otherwise noted. SCREEN ACTION Select “System Settings” The System displays the following options: System Settings Entry Delay 1 Entry Delay 2 Exit Delay...
  • Page 42 LYNX Touch Installation and Setup Guide Programming the Control SCREEN ACTION Select “Quick Arm”. The System toggles between Yes and No. Quick Arm Select “Quick Exit”. The System toggles between Yes and No. Quick Exit Select “Restart Exit Time”. The System toggles between Yes and No. Restart Exit Time SIA: The LYNX Touch default is “Yes”.
  • Page 43: Communications Diagnostics

    LYNX Touch Installation and Setup Guide Programming the Control Communications Diagnostics Communications Status – The system provides a status of the IP or GSM communications paths and performs a self-test of the AES encryption algorithm as follows: Message Meaning GSM: Normal;...
  • Page 44: Communications Id Numbers

    LYNX Touch Installation and Setup Guide Programming the Control Communications ID Numbers – Displays programmed SIM card information Message Meaning MAC Address indicates the unique identification number for installed MAC: xxxxxxxxxxxx communications module(s) MAC CRC: xxxx MAC CRC number for installed communications module(s) WiFi:* xxxxxxxxxxxx Physical MAC Address of the WiFi module...
  • Page 45: Setup Communications

    Log in and follow the on-screen prompts. If you are not signed up for this service, click on “Dealer Signup” from the login screen to gain access to the Honeywell web-based programming. Dealer Sign-Up Direct Link: https://services.alarmnet.com/AlarmNetDirectP_Sign-Up. You will be instructed how to proceed upon completing the sign-up form. Only one sign-up per dealer is required.
  • Page 46: Register Device With Pin

    LYNX Touch Installation and Setup Guide Programming the Control During the registration process the following messages may be displayed: Message Meaning Getting Configuration File… The configuration file is obtained from AlarmNet if the module was programmed through AlarmNet Direct or a previously programmed module was defaulted. Registering…...
  • Page 47: Update Server

    LYNX Touch Installation and Setup Guide Programming the Control Update Server This procedure is used to upload the Configuration File to the Server. SCREEN ACTION 1. Select “Comm. Diagnostics” The System displays the following options depending upon the communication device that is installed: Comm.
  • Page 48: Enroll Using Scan Access Points

    LYNX Touch Installation and Setup Guide Programming the Control ACTION SCREEN 2. Select “WiFi Location”. The System will scroll between “None” and “Speaker Side”. After WiFi Location selecting “Speaker Side”, the “Configure WiFi” option will be displayed. None 3. Select “Configure WiFi”. The following options will be displayed”: Scan Access Points Manually Configure AP * If available...
  • Page 49: Wifi Protected Set-Up (Wps)

    LYNX Touch Installation and Setup Guide Programming the Control 5. Select “DHCP”. The system scrolls between “Yes” and “No”. If “No” is selected the “Static” button is displayed. Note: When entering a password, up to 31 characters can be entered. The system will only display the first 22 characters but will accept up to 31.
  • Page 50: Remote Programming/Control (Downloading)

    LYNX Touch Installation and Setup Guide Remote Programming/Control (Downloading) General Information The control panel can be remotely programmed from an IBM-compatible Personal Computer (PC), Compass Downloader, a HAYES compatible Modem or via a capable GSM or IP Communications Module. When connected to the COMPASS Downloader –...
  • Page 51: Remote Programming Advisory Notes

    LYNX Touch Installation and Setup Guide Remote Programming/Control (Downloading) Remote Programming Advisory Notes • A copy of the program downloaded may be printed using the IBM PC-compatible computer’s internal report generator, when an optional printer is connected (consult your PC manual for proper printer and connections).
  • Page 52: System Operation

    LYNX Touch Installation and Setup Guide System Operation Key/Touchscreen Operation The keys and touchscreen allows the user to arm and disarm the system, and perform other system functions, such as bypassing zones. Zone and system conditions (ALARM, trouble, bypass) are displayed on the display.
  • Page 53: Secondary User Codes

    LYNX Touch Installation and Setup Guide System Operation Secondary User Codes In normal operation mode, the Master Security Code can be used to assign up to 14 secondary 4-digit security codes, including a Babysitter Code and a Duress Code. The Master Code can also be used to remove secondary codes from the system (individually).
  • Page 54: Follow Me" System Announcement Feature

    LYNX Touch Installation and Setup Guide System Operation “Follow Me” System Announcement Feature This feature allows the LYNX Touch to deliver a voice system message to the user phone numbers programmed by the installer. The LYNX Touch will first transmit reports to the Central Station and after receiving its kiss-off the system will dial the user phone numbers and begin transmitting the welcome message “System Message, Press Star to Play”.
  • Page 55: Follow Me" Reminder Feature

    LYNX Touch Installation and Setup Guide System Operation “Follow Me” Reminder Feature This feature allows the user to schedule a time driven message. When activated, the system will dial the User 1 and/or User 2 phone numbers, which are programmed as Phone 1 and Phone 2 respectively by the installer (in the Reporter Programming section), and deliver a recorded message.
  • Page 56: System Displays

    LYNX Touch Installation and Setup Guide System Operation System Displays The following icons will be displayed on the Home screen along with specific zone status information (if applicable) to indicate system status. DISPLAY DEFINITION DISPLAY DEFINITION DISPLAY DEFINITION AC Loss Door Open Fault * Garage Door...
  • Page 57: Audio Alarm Verification (Two-Way Voice Feature)

    LYNX Touch Installation and Setup Guide System Operation Audio alarm verification has not been evaluated by UL. Audio Alarm Verification (Two-Way Voice Feature) This feature allows the central station operator to listen, talk to or conduct a two-way conversation with an individual(s) at the premises.
  • Page 58: Event Log

    System Operation Event Log The LYNX Touch Series event log is capable of recording and displaying up to 128 system events. The type of events that can be recorded is selectable and is programmed in the System Type programming field. The event log can be reviewed by entering the Installer Programming or Master User Programming mode.
  • Page 59: Test Modes

    LYNX Touch Installation and Setup Guide System Operation Central Station Messages The following messages are sent by the L5100 communications modules (GSMVLP5-4G/GSMVLP5CN4G, ILP5 and L5100-WiFi) for the conditions listed below. Alarm Condition Alarm Code Restore Code Power On / Reset E339 C0803 Primary Communication Path Supervision E350 C0951...
  • Page 60: Zone Discovery Mode

    LYNX Touch Installation and Setup Guide Testing the System TO THE INSTALLER Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system. The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as acquainting the user with the proper operation and limitations of the alarm system and its component parts.
  • Page 61: Testing The System

    LYNX Touch Installation and Setup Guide Testing the System 2. If the test is successful the system will send the Manual Trigger Test Report (E601) to the Central Station. The test will not be recorded in the Event Log. 3. The system will make eight attempts to test the dialer for the Primary and eight attempts to test the Secondary Central Station.
  • Page 62 LYNX Touch Installation and Setup Guide LYNX Touch Programming Default Values Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Installer Code 4112 4112 4112 4112 System Type RF Jam Disabled Disabled Disabled Disabled Speaker Phone Enabled Enabled Enabled Enabled Two Way Voice Disabled...
  • Page 63 LYNX Touch Installation and Setup Guide LYNX Touch Programming Default Values Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Secondary CS info None None None Phone Type None Communicator Type None None None None Blank Blank Blank Blank Phone Number Account Number FFFF...
  • Page 64: Lynx Touch Programming Default Values

    LYNX Touch Installation and Setup Guide LYNX Touch Programming Default Values Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Downloader Phone Answer Ans. Machine Defeat Modem Speed (Future Use) Slow Slow Slow Slow Ring Counter Callback Number Blank Blank Blank Blank...
  • Page 65 LYNX Touch Installation and Setup Guide LYNX Touch (L5100CN) Canada Programming Default Values Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Installer Code 4112 4112 4112 4112 System Type RF Jam Disabled Disabled Disabled Disabled Speaker Phone Enabled Enabled Enabled Enabled...
  • Page 66: Zone Programming Default Values

    LYNX Touch Installation and Setup Guide LYNX Touch (L5100CN) Canada Programming Default Values Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Secondary CS Info None None None Phone Type None Communicator Type None None None None Blank Blank Blank Blank Phone Number...
  • Page 67 LYNX Touch Installation and Setup Guide LYNX Touch (L5100CN) Canada Programming Default Values Program Function Configuration 1 Configuration 2 Configuration 3 Configuration 4 Downloader Phone Answer Ans. Machine Defeat Modem Speed (Future Use) Slow Slow Slow Slow Ring Counter Callback Number Blank Blank Blank...
  • Page 68 LYNX Touch Installation and Setup Guide Zone Programming Default Values Zone Assignment/Alarm Response Types for Configuration 1 Zone Loop Supervision/ Device Type Response Type Report Chime Zone Descriptor Number Number Input Type EOLR Door Entry Exit 1 Supervised Front Door Entry Exit 1 Supervised Back...
  • Page 69: Limitations Of This System Statement

    LYNX Touch Installation and Setup Guide Zone Programming Default Values Zone Assignment/Alarm Response Types for Values 3 and 4 Zone Loop Supervision/ Device Type Response Type Report Chime Zone Descriptor Number Number Input Type EOLR Door Entry Exit 1 Supervised Front Door Entry Exit 1...
  • Page 70: Regulatory Agency Statements

    LYNX Touch Installation and Setup Guide Regulatory Agency Statements Federal Communications Commission (FCC) Part 15 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 71 LYNX Touch Installation and Setup Guide WARNING THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced design security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons.
  • Page 72: Ul Notices

    LYNX Touch Installation and Setup Guide UL Notices 1. For UL Residential Burglar Alarm installations with line security, total exit delay time must not exceed 60 seconds. For UL Burglar Alarm installations without line security, total exit delay time must not exceed 120 seconds. 2.
  • Page 73: Sia Quick Reference Guide

    LYNX Touch Installation and Setup Guide SIA Quick Reference Guide Programming Section Feature Range Shipping Default SIA Requirement Installation and Setup Guide or Programming Guide Exit Error Enabled or Disabled Enabled Enabled Reporter/ Report Selection Recent Closing Enabled or Disabled Enabled Enabled Alarm Cancel...
  • Page 74: Specifications

    LYNX Touch Installation and Setup Guide Specifications LYNX Touch Series Security Controls Physical: Dimensions: 8.5” W x 6” H x 1.875” D Electrical: Voltage Input: 9 Vdc from plug-in 2.7A power supply Rechargeable Backup Battery: Nickel-metal hydride battery pack rated at 7.2 Vdc...
  • Page 75: Contacting Technical Support

    Note the proper model number of this product, and the version level (if known) along with any documentation that came with the product. • Note your Honeywell customer number and/or company name. Having this information handy will make it easier for us to serve you quickly and effectively. Technical Support : ......................
  • Page 76: Glossary

    LYNX Touch Installation and Setup Guide Glossary AES – Advanced Encryption Standard APL – Advanced Protection Logic dBM – decibals milliwatt (power ratio) DHCP – Dynamic Host Configuration Protocol, which provides a mechanism for allocating IP addresses dynamically so that addresses can be reused when hosts no longer need them. DNS –...
  • Page 77: Index

    LYNX Touch Installation and Setup Guide – Index – 24-Hour Silent ............... 52 300-03864-1 ..............5 Enroll The WiFi Module ..........47 300-03866 ................. 5 Enter Installer Programming Mode ......18 300-04063 ..............5, 9 Enter/Change The Master Code ........52 300-04065 ..............
  • Page 78 LYNX Touch Installation and Setup Guide Master Code ..............52 Secondary User Codes ........... 53 Master Security Code ............ 53 Security Code ..............40 Master User Security Code ........... 52 Security Code Handshake ..........50 Security Codes ............... 52 Memory of Alarm ............52 Setup Communication ...........
  • Page 79: Summary Of Connections Diagram

    LYNX Touch Installation and Setup Guide Notes: Connection of the fire alarm signal to a fire alarm headquarters or a central station shall be permitted with the approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police emergency number.
  • Page 80: Warranty Information

    WARRANTY INFORMATION For the latest warranty information, please visit: www.honeywell.com/security/hsc/resources/wa 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright © 2012 Honeywell International Inc. www.honeywell.com/security Ê800-10614V1}Š 800-10614V1 12/12 Rev. A...