OPERATING APPLIANCE

FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: Keep flue open when operating unit.
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
CURING
During the 2-3 hour appliance break-in period, you may detect
an odor from the appliance as the various paints and com-
pounds used in the manufacturing of this log set cure. This is a
normal and temporary situation that is not cause for alarm.
However, you may want to provide extra ventilation to the room
during this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1 hour.
• Burn the logs in consecutive 1 hour periods raising the flame
an additional 2" to full flame height for a total of three hours.
LIGHTING
INSTRUCTIONS
1.
STOP! Read the safety information, above.
2.
Make sure equipment shutoff valve is fully open.
3.
Press in and turn control knob clockwise
OFF position.
4.
Wait five (5) minutes to clear out any gas. Then smell for gas
around log set and near floor. If you smell gas, STOP! See
Safety Information, page 2. If you don't smell gas, go to the
next step.
109220-01C
LOGS
For Your Safety Read Before Lighting
5. Turn control knob counterclockwise
position and press in. Keep control knob pressed in for five
(5) seconds.
Note: You may be running this log set for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up when released, contact a
qualified service person or gas supplier for repairs.
6. With control knob pressed in, push down and release igni-
tor button. This will light pilot. Visually locate the pilot on
the control valve cover by the edge of the burner pan to
look for flame. If needed, keep pressing ignitor button un-
til pilot lights.
Note: If pilot does not stay lit after several tries, turn the
gas control knob to OFF and call your service technician
or gas supplier.
7. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7.
8. Turn control knob counterclockwise
position. Burner should light. If burner does not light, call
a qualified service person.
Ignitor
Figure 15 - Ignitor and Control Knob
Pilot
Burner
to the
Figure 16 - Thermocouple and Pilot
OPERATING APPLIANCE
Curing Logs
Lighting Instructions
to the PILOT
Control Knob
Pilot
ON
OFF
FROM "PILOT" POSITION
SLIGHT PUSH TO
Off
On
TURN OFF
PULL PUSH
Thermocouple
9 9
to the ON
Table of Contents