SPECIFICATIONS

Type
Model name
Power sourse
Available voltage range
Starting current
Airflow
rate
Fan
Type × Q'ty
Motor output
Sound pressure level
Heat exchanger type
Type × Q'ty
Compressor
Motor output
Refrigerant
Refrigerant oil
Enclosure
Net
Dimensions
(H × W × D)
Gross
Net
Weight
Gross
Size
Method
Connenction pipe
Pre - charge length
Max. length
Max. height difference
Operation range
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 80°F (26.67°C) DB / 67°F (19.44°C) WB, and outdoor temperature of 95°F (35°C) DB / 75°F (23.9°C) WB.
Heating : Indoor temperature of 70°F (21.11°C) DB / 59°F (15°C) WB, and outdoor temperature of 47°F (8.33°C) DB / 43°F (6.11°C) WB.
Pipe length : 24ft.7in (7.5m), Height difference:0 m. (Outdoor unit - Indoor unit)
The protective function might work when using it outside the operation range.
A
Cooling
CFM
3
(m
/h)
Heating
W
Cooling
dB (A)
Heating
in.
Dimensions
(H × W × D)
mm
Fin pitch
FPI
Rows × Stages
Pipe type
Fin Type
W
Type
lbs.oz.
Charge
kg
Type
Material
Color
in.
mm
in.
mm
lbs.(kg)
Liquid
in. (mm)
Gas
ft. (m)
Cooling
°F (°C)
Heating
- (02 - 01) -
INVERTER HEAT PUMP
AOU9RLS2
AOU12RLS2
208 / 230V
~
187 - 253V
~
3.7
5.5
1082 (1840)
1082 (1840)
Propeller fan × 1
115
48
49
49
50
23-5/32 × 34-11/16 × 1-7/16
588 × 881 × 36.4
20
2 × 28
Copper
Aluminum
Rotary × 1
850
R410A
2lbs.10oz.
1.20
FREOL α68SZ
Steel
Beige
Approximate color of MUNSELL 10YR7.5/1.0
24 - 1/2 × 31 - 3/32 × 11 - 11/32
620 × 790 × 290
28 - 1/16 × 37-7/32 × 15 - 9/16
713 × 945 × 395
84 (38)
93 (42)
Ø 1/4 (Ø 6.35)
Ø 3/8 (Ø 9.52)
Flare
49 (15)
66 (20)
49 (15)
14 to 115 (-10 to 46)
-5 to 75 (-21to 24)
AOU15RLS2
60Hz
60Hz
6.1
1206 (2050)
51
51
1000
2lbs.12oz.
1.25
86 (39)
95 (43)
Ø 1/2 (Ø 12.7)