Sumo SMK36GEN Safety And Operating Manual

Sumo SMK36GEN Safety And Operating Manual

1100w portable generator
Table of Contents
loading

Summary of Contents for Sumo SMK36GEN

  • Page 2 SMK36GEN 1100w PORTABLE GENERATOR SAFETY AND OPERATING MANUAL...
  • Page 3 GUARANTEE This Sumo product carries a guarantee of 12 months. If your product develops a fault within this period, you should, in the first instance contact the retailer where the item was purchased.
  • Page 4: Safety Instructions

    PLEASE NOTE: The generator supplied is NOT suitable for providing power to any electronic products such as computers, laptops or televisions etc. If in doubt please refer to the specific product manual for advice on supply connection. If using for a caravan, motor home or boat etc refer to the manufacturers manual regarding connection of a generator.
  • Page 5 5) Service a) Have your power tool serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained. 1100w PORTABLE GENERATOR SMK36GEN...
  • Page 6 ADDITIONAL SAFETY INSTRUCTIONS FOR YOUR GENERATOR Electrical generators must always be grounded, (connected to earth). Petrol or diesel powered generators must never be used in an unventilated closed spaces.The exhaust fumes are highly dangerous and can cause “Carbon Monoxide Poisoning” which will cause drowsiness and death.
  • Page 7: Electrical Generator

    Before transporting the generator in a vehicle, drain all fuel to prevent leakage. To prevent an electric shock and fire, never connect an electrical load with the electrical output switched on. Do not connect the generator to any other electrical source. 1100w PORTABLE GENERATOR SMK36GEN...
  • Page 8 The engine speed has been factory set to provide safe operation.Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire. Never attempt to “speed- up” the engine to obtain more performance. Both the output voltage and frequency will be thrown out of standard by this practice, endangering attachments and the user.
  • Page 9 Choke lever AC socket Engine switch Ground (earth) terminal Oil drain plug Recoil starter AC circuit breaker 10 DC Socket 11 DC circuit breaker 12 Pilot light 13 Voltmeter 14 DC charging leads 15 Spark plug spanner 1100w PORTABLE GENERATOR SMK36GEN...
  • Page 10: Technical Data

    TECHNICAL DATA AC output 230Vac ~ 50Hz Rated power 0.9kVA Peak power 1.1KvA Phase Single Power factor cosø=1 Displacement 87cc DC output 12V, 5.3A Motor 2.2HP, 4 stroke Fuel tank capacity Fuel type Unleaded Petrol Oil type SAE 10W-30 Spark plug type E6TC NOISE DATA Sound power level declared...
  • Page 11: Operation Instructions

    Spike is pushed into the ground by at least 100mm so that it is firm and a litre of water poured around it to ensure good Earth continuity. 1100w PORTABLE GENERATOR SMK36GEN...
  • Page 12: Checking The Oil

    2. CHECKING THE OIL Warning: the generator is supplied without oil and must be filled before first use, failure to do so will invalidate your guarantee. Before checking or refilling oil, be sure the generator is put on a stable and level surface with the engine stopped.
  • Page 13: Overload Protection

    (See Fig 8).The a.c. overload protection device can be re-set by pressing in the re-set button (See Fig 9). Fig 9 1100w PORTABLE GENERATOR SMK36GEN...
  • Page 14: Maintenance

    7. DC BATTERY CHARGING FUNCTION This function is applicable to 12V battery charging only. Disconnect the leads from the battery. Loosen the vents on the battery. Make sure the battery fluid level is correct Using a hydrometer measure the specific gravity of the battery fluid and calculate the charging time in accordance with the table shown in Fig 10.
  • Page 15: Spark Plug

    Never run the engine without the air filter. Fuel tank filter Remove the fuel tank filler cap and the filter (Fig 15), clean the filter thoroughly using an environmentally friendly water based degreasing agent and re-fit. Fig 15 1100w PORTABLE GENERATOR SMK36GEN...
  • Page 16: Maintenance Schedule

    STORAGE If the generator is not to be used or is to be stored for more than one month the following storage procedure should be carried out. Drain all the fuel from the fuel tank and the carburettor, ensure that all the fuel has been removed.
  • Page 17: Engine Troubleshooting

    Improper adjustment fuel of carburetor Good spark Engine runs erratically Insufficient Pull rope sharply pulling speed for starting rope Wrong grade of Check grade of fuel fuel used Overloading Check the working conditions Overheating 1100w PORTABLE GENERATOR SMK36GEN...
  • Page 18: Generator Trouble Shooting

    GENERATOR TROUBLE SHOOTING CONDITION PROBABLE CAUSE CORRECTIVE ACTION Tripped circuit breaker Reset Check and repair Poor connection or faulty lead No AC output Broken recepticle Faulty circuit breaker Check and repair No AC output Generator problem Output power too Engine RPM set too No load speed set high or low high or low...
  • Page 19 1100w PORTABLE GENERATOR SMK36GEN...
  • Page 20: Declaration Of Conformity

    We, Importer Powersmith Ltd. BA22 8RT Declare that the product 1100W Generator SMK36GEN Complies with the essential health and safety requirements of the following directives: 89/336/EEC - EMC Directive. 2006/95/EC - Low Voltage Directive. 98/37/EEC - Machinery Directive. 2000/14/EC - Noise Directive.