Checking the MPxIO Multipath Status

Use the "format" command to check the MPxIO multipath status after multipathing is set up
(example output follows).
Example: ETERNUS8000
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c1t0d0
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0113ce2e1,0
1. c7t6000B5D0006A0000006A010900000000d0
sec 256>
Use the "luxadm" command to check that each path in the multipath configuration is normal.
Example: ETERNUS8000
# luxadm display /dev/rdsk/c7t6000B5D0006A0000006A010900000000d0s2
DEVICE PROPERTIES for disk: /dev/rdsk/c7t6000B5D0006A0000006A010900000000d0s2
Vendor:
Product ID:
Revision:
Serial Num:
Unformatted capacity: 10240.000 MBytes
Write Cache:
Read Cache:
Minimum prefetch:
Maximum prefetch:
Device Type:
Path(s):
/dev/rdsk/c7t6000B5D0006A0000006A010900000000d0s2
/devices/scsi_vhci/ssd@g6000b5d0006a0000006a010900000000:c,raw
Controller
Device Address
Host controller port WWN
Class
State
Controller
Device Address
Host controller port WWN
Class
State
Refer to the "Sun StorEdge Traffic Manager Installation and Configuration Guide" on the Oracle
web-site (http://www.oracle.com/) for details.
P3AM-2722-04ENZ0
ETERNUS Disk storage systems Server Connection Guide for Oracle Solaris
c2 and c3 paths changed to c7 path,
making a multipath configuration.
/scsi_vhci/ssd@g6000b5d0006a0000006a010900000000
FUJITSU
E8000
0000
6A0109
Enabled
Enabled
0x0
0x0
Disk device
/devices/pci@0,600000/pci@0/pci@8/pci@0,1/QLGC,qlc@1/fp@0,0
500000e0d0400206,0
2100001b320aca5b
primary
ONLINE
/devices/pci@0,600000/pci@0/pci@8/pci@0,1/QLGC,qlc@1,1/fp@0,0
500000e0d0400287,0
2101001b322aca5b
primary
ONLINE
11
Both path States show as "ONLINE"