3.3.15 Regi. / Feed / Empty sensor
1. Remove the cassette and duplex unit.
2. Remove the PLATE-FRAME BOTTOM after
removing 4 screws.
3. Remove the sensor cover after removing 2
screws.
Service Manual
ML-331x/371x series
CÓPIA NÃO CONTROLADA
3. Disassembly and Reassembly
4. For the sensor to require replacement, unplug
the connector then replace it.
5. Remove the sensor cover after removing
2 screws.
3-14
CÓPIA NÃO CONTROLADA
Regi. sensor
Regi. sensor
Feed sensor
Feed sensor
Samsung Electronics