XCP Issues Fixed in Releases Earlier Than XCP 1091 (Continued)
TABLE 6
ID
Description
RTIF1-
Some commands that update configuration
070418-011
data take a relatively long time to execute.
RTIF1-
The fault (memory.block.ue) is encountered
070418-012
and reported periodically.
RTIF1-
When using the XSCF Web to import a
070418-020
firmware image, if the image is corrupted (for
example, if the browser window is closed
during import), the flashupdate command
might later report an internal error.
CR ID 6537996 is similar.
RTIF1-
Attempting to move a COD board using the
070418-021
moveboard(8) command might fail.
RTIF1-
The XSCF firmware monitors itself and if it
070418-022
detects any anomolies, it will force a reboot.
RTIF1-
Using the rebootxscf(8) command may
070418-023
result in a process down error, and possibly an
FMA event with MSG ID SCF-8005-NE.
RTIF1-
showaudit all shows a long list of defaults
070418-025
in the policy section after the database is
cleared.
RTIF1-
When you have updated the /etc/ttydefs
070528-001
file of Solaris to disable the console flow
control, you cannot disable the console flow
control on the telnet via a server.
RTIF1-
When connected to telnet, the login or the
070802-001
password prompt doesn't appear.
RTIF1-
Using the XSCF Web, when you selected SSH
070823-001
on the snapshot screen, the maximum number
of character input for Host, Directory, ID, and
Password doesn't correspond to the maximum
number of character input on the XSCF Shell.
22
SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1091 • April 2010
Workaround
Do not cancel set* commands. They appear to
hang, but eventually complete in about 30
seconds.
An uncorrectable error exists in a DIMM and
the DIMM should be replaced.
Use the command getflashimage -d to
delete the corrupted image. If necessary, reboot
the XSCF Unit, then use the flashupdate
command again to clear the internal error.
Use the deleteboard(8) and addboard(8)
commands instead of the moveboard(8)
command.
Allow the XSCF Unit to finish rebooting. It will
return to normal operation within
approximately 5 minutes.
Ignore this event.
Update the database with the following:
setaudit -a opl=enable
setaudit -a opl=default
No workaround is available.
Disconnect the telnet session and try again.
To specify the value which exceeds the
maximum number of character input for the
XSCF Web, use XSCF Shell.