Sensor Disconnection Mode; High Temperature Alarm Mode - Panasonic SD-257WST Service Manual

Automatic bread maker
Table of Contents
5.1.1.2.

Sensor disconnection mode

When the disconnection of a sensor is detected, all load of the
device goes off in this mode.
Indication on LCD
• "H01" is displayed on the LCD during the sensor disconnec-
tion. ("H01" is brinking)
5.1.1.3.

High temperature alarm mode

When the "Start" key is pressed when the unit is in the hot con-
dition at a temperature of more than 40 deg.C, the buzzer
sounds, the LED goes on and off, and the other load goes off in
this mode.
* The high temperature alarm mode does not occur at the
"BAKE ONLY" menu rebaking setting.
Behaviour of restoration from high temperature alarm
mode
• When the unit temperature is less than 40 deg.C, and more
than 10 seconds passes after the high temperature alarm
mode has begun, the buzzer sounds once and the high tem-
perature alarm mode is canceled. (No indication on LCD)
Indication on LCD
• "TEMP" is displayed on LCD. ("TEMP" is brinking)
14