6.4 Flow chart for the defrosting management

More than 5 h elapsed after power on &
compressor off or compressor on for more
than 2,5 h?
yes
DEFROSTING
Resetting door accumulated timer
More than 30 h elapsed after the last
defrosting & cooler or freezer door is open
from more than 1 minute
no
More than 14 h elapsed after the last
defrosting & comp on for more than 2,5 h?
no
More than 14 h elapsed after the last
defrosting & last defrosting lasted 60 min-
no
More than 30 hours elapsed after the last
defrosting (for the first time)?
no
More than 72 h elapsed after the last
defrosting?
no
DEFROSTING
- ITZAA
START
utes?
no
yes
yes
yes
yes
yes