Environmental Specifications; Power Specifications - Cisco UCS C200 Installation And Service Manual

Hide thumbs Also See for UCS C200:
Table of Contents

Environmental Specifications

S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
Environmental Specifications
Table A-2
Table A-2
Description
Temperature, operating:
Derate 1°C for every 1000 ft (304 m) up to a
maximum altitude of 10,000 ft (3048 m)
Temperature, nonoperating
within altitude: 0 to 40,000 feet (0 to 12,000
meters)
Humidity (RH), noncondensing
Altitude
Sound power level
Measure A-weighted per ISO7779 LwAd (dBA)
Operation at 73°F (23°C)
Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)

Power Specifications

Table A-3
Table A-3
Description
AC-input voltage
AC-input frequency
Maximum AC-input current
Maximum output power for each power
supply
Power supply output voltage
You can get more specific power information for your exact server configurationby using the Cisco UCS
Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
Cisco UCS C200 Server Installation and Service Guide
A-2
lists the environmental specifications for the server.
Environmental Specifications
lists the specifications for each power supply.
Power Supply Specifications
Appendix A
Specification
50 to 95°F (10 to 35°C)
–40 to 149°F (–40 to 65°C)
5 to 93%
0 to 10000 feet
54.7 dBA
5.7 Bels
Specification
115 to 230 VAC nominal
(Range: 90 to 264 VAC)
50 to 60 Hz nominal
(Range: 47 to 63 Hz)
10 Amps
650 W (up to two power supplies can be installed)
Main power: 12 VDC
Standby power: 5 VDC
Technical Specifications
OL-20732-02
Table of Contents
loading

This manual is also suitable for:

Ucs c200 m1Ucs c200 m2