Auto Cleaning

• Function used to perform the Self Cleaning to prevent the Unit from Fungus and Bad Odors.
• Used after the Shut Down of Cooling Operation to Clean the Evaporator and keep it as fresh for the Next operation.
• During Self Cleaning the Outdoor Unit is Switched off.
• The function is easy to be operated as It is accessed through the Remote Controller.
ON
Cooling Start
25 Sec
Comp.
On
Off
Indoor Fan

Auto Changeover

• The air conditioner changes the operation
mode automatically to keep indoor tempera-
ture.
• When room temperature vary over ±2°C with
respect to setting temperature, air condition-
er keeps the room temperature in ±2°C with
respect to setting temperature by auto
change mode.
Low Ambient
• If outdoor temperature drops below certain temperature,liquid back is prevented by reducing fan speed.
It can prevent frosting of evaporator and keep cooling operation
• No matter even if the outdoor temperature reaches -10°C.
• You can Cool your room at your desired temperature all your around.
Freq.
On
On
Off
36 Room Air Conditioner
OFF
Cooling CYCLE
ON
Setting Step
Comp Freq.
Outdoor fan
Outdoor pipe temp.
°
0°C outdoor fan On/Off
control
Off
°...
Outdoor temp.
- 0°C
Cleaning
30 Min
OFF
S-Low
Outdoor temp.
Indoor temp.
+ 2°C
+ 1°C
+ 0.5°C
Set Temp.
- 0.5°C
- 1°C
- 2°C
Auto
Change
COOLING
Mode.
25
Cond . temp.
20
15
10
Outdoor fan On/Off control
5
0
0
50
-5
Outdoor
temp.
HEATING
Outdoor temp.:-10°C
100
150
200
Time(Min.)
30°C
20°C
10°C