5.1.18 Fixing Unit

(1) Disconnect the heater harness connector and thermistor harness connector.
(2) Remove the two cup B M4x12 taptite screws, and then remove fixing unit.
Taptite, cup B M4x12

Fixing unit

1
Taptite, cup B M4x12
Heater harness
3
2
Thermistor harness
NOTE: Be sure not to touch the pressure roller.
(3) Remove the two PR spring.
(4) Remove the pressure roller ASSY (pressure roller, PR arm ASSY, PR bush) from the fuser
frame.
PR arm ASSY
Hook
2
PR spring
Pressure roller
PR spring
3
Hook
2
PR arm ASSY
"A"
Hook
1
Fuser frame
PR spring
"A"
"A"