1. Specification

Indoor Unit

Indoor Unit
Nominal Capacity
Cooling
(Min~Rating~Max)
Heating
Nominal Input
Cooling
(Min~Rating~Max)
Heating
Indoor Unit
Nominal Capacity
Cooling
(Min~Rating~Max)
Heating
Nominal Input
Cooling
(Min~Rating~Max)
Heating
Indoor Unit
Nominal Capacity
Cooling
(Min~Rating~Max)
Heating
Nominal Input
Cooling
(Min~Rating~Max)
Heating

Outdoor Unit

Indoor Unit
Running Current(Rating) Cooling
Heating
Starting Current
Cooling/Heating
Power Supply
Power Supply Cable(Outdoor)
Power and Transmission Cable(Outdoor to Indoor or Outdoor to BD)
Dimensions
W x H x D
Net Weight
Type
Compressor (#1)
Qty x Model
Oil charge volume
Oil Type
Cycle Charge (at 7.5m)
Refrigerant
Type
Control
Additional Refrigerant Charge
(Rows x Column x FPI) x No.
Heat Exchanger
Defrosting Method
Capacitor
Fan
Drive
Discharge Direction(Side/Top)
Air Flow Rate x No. of Fan
Sound Level(H/L)
Sound Pressure
Piping Connections
Liquid(Cycle A)
Gas(Cycle A)
Max. Interunit
Total Piping
Piping Length
Main Piping
Max. Elevation
Outdoor Unit~Indoor Unit
Difference
Indoor Unit~Indoor Unit
Operation Range
Cooling
(Outdoor)
Heating
Note:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
kW
Btu/h
kW
Btu/h
kW
kW
kW
Btu/h
kW
Btu/h
kW
kW
kW
Btu/h
kW
Btu/h
kW
kW
A
A
A
Ø / V / Hz
No.x mm
2
No.x mm
2
mm
kg(lbs)
cc
g
g/m
µF/Vac
CMM
dB(A)+3
mm(inch)
mm(inch)
m
m
m
m
˚C
˚C
2. Wiring cable size must comply with the applicable local and national
code.
3. The specification may be subject to change without notic for purpose
of improvement.
- 2 -
ATNH42GMLED [UT42 NMD]
5.0~12.5~13.8
17,060~42,650~46,910
5.6~14.0~15.4
19,108~47,770~52,547
3.90
3.88
ABNH426RLAD [UB42 NRD]
5.0~12.5~13.8
17,060~42,650~46,910
5.6~14.0~15.4
19,108~47,770~52,540
4.15
3.88
AVNH426LLAD [UV42 NLD]
5.0~12.5~13.8
17,060~42,650~46,915
5.6~14.0~15.4
19,108~47,770~52,547
4.15
3.88
AUUW426D [UU42W U3D]
17.7
16.7
-
1/220-240V/50
3*5.0(Including Earth)
4*0.75(Including Earth)
950*1 380*330
103(227)
Rotary
5JD420XAD22
13 000
FVC68D
3 600
R410A
E.E.V
40
(2*32*17)*2
Reversing cycle
-
Direct Drive
Side
110
55/51
9.52(3/8)
15.88(5/8)
75
30
30
1
-10~46
-15~24
LGE Internal Use Only