NEC N8100-1573F User Manual page 123

Express5800/ir110a-1h
Table of Contents
Setting of Priority of Background Task
LSI Software RAID Configuration Utility displays and sets priority of background tasks (Rebuild,
Patrol Read, and Consistency Check) by percentage. However, Universal RAID Utility uses three
levels as High/Middle/Low for them.
The setting value of LSI Software RAID Configuration Utility and the display level of Universal
RAID Utility
Item
Rebuild Priority
Patrol Read Priority
Consistency Check Priority
The setting level of Universal RAID Utility and the setting value of LSI Software RAID
Configuration Utility
Item
Rebuild Priority
Patrol Read Priority
Consistency Check Priority
NOTES:
LSI Software RAID Configuration Utility can set BGI Rate
(Background Initialize Priority). However, Universal RAID Utility
cannot set it.
Universal RAID Utility can set Initialization Priority (Full
Initialization), however, it cannot be set to the LSI Embedded
MegaRAID.
Setting value of LSI Software
RAID Configuration Utility
15 to 100
8 to 14
0 to 7
15 to 100
8 to 14
0 to 7
15 to 100
8 to 14
0 to 7
Setting level of Universal
RAID Utility
High
Middle
Low
High
Middle
Low
High
Middle
Low
Configuring Your Server 4-47
Universal RAID Utility Level
High
Middle
Low
High
Middle
Low
High
Middle
Low
Setting value
20
10
5
20
10
5
20
10
5