GE RHM 04 Overwiew And Specifications
GE RHM 04 Overwiew And Specifications

GE RHM 04 Overwiew And Specifications

Measurement & control versatile coriolis mass flowmeter with fast response times for very high pressure applications

Quick Links

GE
Measurement & Control
RHM 04
Versatile Coriolis Mass
Flowmeter with Fast
Response Times for Very
High Pressure Applications
The RHM 04 can measure flow rates up to 10 kg/min
(22 lb/min) with extremely fast response times and
excellent repeatability. A very high pressure version
up to 1067 bar is also available, manufactured by
GE's Rheonik mass flowmeter experts.
Applications
• General control • Dosing
• Batching
• Injections
Features
• Available as very high pressure version up to 1067
bar
• Response times of 30 ms and better
• Flow uncertainty down to 0.10%
• Repeatability better than 0.05%
• Unique torsion oscillator
• Typical measuring ranges from 0.1 to 10 kg/min
• Minimal flows as low as 50 g/min
• Customization possible
• Extra compact design with minimal space
requirement
• Hazardous Area Approvals (ATEX, CSA, ...)
g
• Mixing
• Filling
Advantages
• Torsion oscillator design assures most stable and
basically drift free measurement and increased
signal to noise ratio
• Not sensitive to changes in pressure
• Longest life time and increased safety (low stress
in welds and increased wall thickness against
abrasion)
• No moving parts, practically no maintenance
• Removable connection manifold available
loading

Summary of Contents for GE RHM 04

  • Page 1 Flowmeter with Fast Response Times for Very High Pressure Applications The RHM 04 can measure flow rates up to 10 kg/min (22 lb/min) with extremely fast response times and excellent repeatability. A very high pressure version up to 1067 bar is also available, manufactured by GE’s Rheonik mass flowmeter experts.
  • Page 2 General Dimensions RHM 04 PM0/SM0 (parallel/serial, manifold construction) Process Connection Face to face length (L) Order Code Standard Flange DIN DN15/PN40 8.66 Flange DIN DN15/PN100 8.66 Flange ANSI ½" 150# RF/SF 8.66 Flange ANSI ½" 300# RF/SF 8.66 Flange ANSI ½'' 600# RF/SF 8.66...
  • Page 3 General Dimensions RHM 04 PF0 (parallel, sealless construction with flange connection) Process Connection Face to face length (L) Order Code Standard Flange DIN DN15/PN40 8.66 Flange DIN DN15/PN100 8.66 Flange ANSI ½" 150# RF/SF 8.66 Flange ANSI ½" 300# RF/SF 8.66...
  • Page 4 General Dimensions RHM 04 SF0 (serial, sealless construction without dead spaces) (*) Process Connection Face to face length (L) Order Code Standard Sanitary ½" Triclamp, DIN 8.66 32676 Sanitary NW10, DIN 11851 8.66 Type single path, welded measuring loops without seals and sanitary connection H2 = 184 mm (7.24 in)
  • Page 5 Pressure Rating RHM 04 The maximum pressure (pmax) of a sensor is determined by its weakest part. The weakest part can be the measuring loops (pmax indicated below) or the construction type (pmax indicated in the Basic Order Code section, last page) or the selected flanges / fittings (for pmax please see respective standard).
  • Page 6 Performance RHM 04 Max Flow Rate Qmax and Qnom (*) = 10 kg/min (22 lb/min) Uncertainty % DP (bar) Standard Models Flow Rate Uncertainty kg/min lb/min in % of reading 10.0 22.05 0.20 15.43 0.20 8.82 0.20 1.10 0.20 0.44 0.50...
  • Page 7 General Specifications RHM 04 Temperature Range • NT Models from -20 to +120°C (-4 to +248°F) • ET Models from -45 to +120°C (-49 to +248°F) • ET2 Models from -45 to +210°C (-49 to +410°F) • ET1 Models from -196 to +50°C (-320 to +122°F) •...
  • Page 8 920-493A © 2013 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.