Technical Specifications - HP 12500 Series Specification

12500 series
QuickSpecs

Technical Specifications

HP 12504 AC Switch Chassis (JC654A)
Ports
Physical characteristics
Memory and processor
Mounting
Performance
Environment
Electrical characteristics Frequency
Safety
Emissions
4 open module slots
2 MPU (for management modules) slots
4 switch fabric slots
Supports a maximum of 128 10GbE ports or 192 Gigabit Ethernet ports, or a combination
Dimensions
Weight
Full configuration weight 220.46 lb (100 kg)
Gigabit Module
10G Module
Management Module
Fabric
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Throughput
Routing/Switching
capacity
Operating temperature
Operating relative
humidity
Nonoperating/Storage
temperature
Nonoperating/Storage
relative humidity
Maximum heat
dissipation
Voltage
DC Voltage
Maximum power rating
Notes
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of
Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03;
Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950-
1:2001; ROHS Compliance
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC
Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
DA - 13785 North America — Version 20 — January 16, 2014
17.4(w) x 27.87(d) x 17.4(h) in (44.2 x 70.8 x 44.2 cm) (10U height)
132.28 lb (60 kg)
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress, shared by
24 1-GbE ports)
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by
2 10GbE ports)
Primary CPU: PowerPC @ 1000 MHz, 128 MB flash, 256 MB compact flash, 4 GB
RAM
PowerPC @ 400 MHz, 128 MB RAM
960 million pps
3240 Gbps
32°F to 104°F (0°C to 40°C)
5% to 95%, non-condensing
-40°F to 158°F (-40°C to 70°C)
5% to 95%, non-condensing
50/60 Hz
8123 BTU/hr (8569.77 kJ/hr)
100-120/200-240 VAC
-48 to -60, rated/-40 to -72, maximum, VDC
2380 W
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with
fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all
modules populated.