Flooring Under The Range - GE JBP19 Use And Care & Installation Manual

Self-cleaning electric range
Table of Contents
PREPARE THE OPENING (cent'd)

Flooring Under the Range

Your range, like many other household
items, is heavy and can settle into soft
floor coverings such as cushioned vinyl or
When moving the range on this type
of flooring, use care, and follow these simple and
inexpensive instructions.
The range should be installed on a
sheet of plywood (or similar material) as follows:
When the floor covering ends at the front of the
the
that the range will rest on should
range,
area
be built up with plywood to the same level or
higher than the floor covering. This will allow
the range to be moved for cleaning or servicing.
STEP 2
PREPARE FOR ELECTRICAL CONNECTION
Use only a 3-conductor, or if required a 4-
conductor range cord set as noted below. These
cord sets are provided with ring type terminals.
the cord must be 125/250
The electrical rating of
volts minimum, 40 amperes.
NOTE: Only a 4-conductor cord is to be used
when the appliance is installed in a mobile home
or where local codes do not permit grounding
through the neutral.
STEP 3
1.
Locate connector block at the bottom rear of
with a knockout ring for accommodating conduit
fittings. Brackets provided are used to support
the flexible cord strain relief, which must be
securely attached to the cord set.
(PROVIDED WIT
SET
NOT PART
STEP 4
3-WIRE SYSTEM
Power Cord Installation-Insert screws
through power cord terminals so that the screws
pass through connector block terminals and
engage nuts. Tighten screws securely.
inch thick
1/4
Cable Direct Installation-Clamp bare wires
between the connector block terminals and
movable nuts with screws tightened securely.
1.
Connect the neutral or grounded wire of the
supply circuit to the neutral terminal of the
connector block, located in the center. The
power leads must be connected to the outside
(brass colored) terminals.
TOR
WARNING: CONNECTOR BLOCK IS
APPROVED FOR COPPER WIRE
i-
CONNECTOR
BLOCK
TERMINAL
Copper Wiring
POWER CORD
TERMINAL
NEUTRAL
TERMINAL
NG STRAP
ING TO RANGE)
31
Table of Contents
loading

Table of Contents