Toshiba TOSVERT VF-AS1 Instruction Manual page 4

Pg feedback board
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents
 Wiring
▼ Be sure to perform the following preparatory work before proceeding to wiring.
Mandatory
Failure to do this preparation could lead to electric shocks.
▼ Tighten the terminal board fixing screws at the specified torque.
Failure to do this could lead to fire.
 About operation
▼ Do not touch inverter terminals when they are energized even if the motor is halted.
Touching terminals while the power is energized could lead to electric shocks.
▼ Do not wipe the body with a wet cloth.
It could lead to electric shocks.
Prohibited
▼ Do not pull on the cable
It could cause damage or error.
 About disposal of Inverter
▼ Dispose of the inverter as an industrial waste.
Unless it is disposed of as an industrial waste, it will become risks for human injury.
Mandatory
Notes on use
▼ Do not install the inverter where the temperature or the humidity will change rapidly.
▼ Keep a distance of 20cm or more between the inverter's power cable and the encoder
cable.
Or the inverter might malfunction because of noise.
Turn the power off.
Wait 15 minutes or more after turning the power off and confirm that the charge
lamp (on the inverter) is extinct.
Using a circuit tester that has a D.C. voltage measuring capacity of more than 800V,
check to see that the voltage remaining in the D.C. main circuit (between PC and
PA) is below 45V.
Warning
Warning
Caution
Notes
3
E6581319
Table of Contents
loading

This manual is also suitable for:

Tosvert vf-ps1

Table of Contents