Frigidaire P/N 134296400A (0404) Installation Instructions Manual

Frigidaire gas and electric dryer p/n 134296400a (0404) installation instructions

Quick Links

Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer
is installed correctly and safely. Leave these instructions near the Dryer after installation for future reference.
NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANSI/NFPA 70 or in Canada, CSA C22.1 Canadian Electrical Code Part 1.
NOTE: The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Fuel Gas Code ANSI Z223.1 or in Canada, CAN/CGA B149.12.
NOTE: The Dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 (latest editions) for HOME USE only.
This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc.
For your safety the information in
this manual must be followed to minimize the risk
of fire or explosion or to prevent property damage,
personal injury or loss of life.
- Do not store or use gasoline or other flammable
vapors and liquid in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
· Do not try to light any appliance.
· Do not touch any electrical switch; do not use
any phone in your building.
· Clear the room, building or area of all
occupants.
· Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
· If you cannot reach your gas supplier, call the
fire department.
Installations must be performed by a qualified or
licensed contractor, plumber, or gasfitter qualified
or licensed by the state, province, or region where
this appliance is being installed.
Printed in U.S.A.
Installation
Instructions
Contents
SUBJECT
Gas & Electric
Dryer
PAGE
2
2
2-3
3
4
5
5-6
6
6
7
7
8
8
9
9
P/N 134296400A (0404)
Table of Contents
loading

Summary of Contents for Frigidaire P/N 134296400A (0404)

  • Page 1: Table Of Contents

    Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer is installed correctly and safely. Leave these instructions near the Dryer after installation for future reference. NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70 or in Canada, CSA C22.1 Canadian Electrical Code Part 1.
  • Page 2: Pre-Installation Requirements

    PRE-INSTALLATION REQUIREMENTS Tools and Materials Required for Installation: 1. Phillips head screwdriver. 2. Channel-lock adjustable pliers. 3. Carpenter's level. 4. Flat or straight blade screwdriver. 5. Duct tape. 6. Rigid or flexible metal 4 inch (10.2 cm) duct. 7. Vent hood. 8.
  • Page 3: Gas Supply Requirements

    MAXIMUM LENGTH of 4” (10.2 cm) Dia. Rigid Metal Duct VENT HOOD TYPE (Preferred) Number Louvered 90° 4” Turns (10.2 cm) 60 ft. (18.28 m) 52 ft. (15.84 m) 44 ft. (13.41 m) 32 ft. (9.75 m) 28 ft. (8.53 m) MAXIMUM LENGTH of 4”...
  • Page 4: Location Of Your Dryer

    LOCATION OF YOUR DRYER DO NOT INSTALL YOUR DRYER: 1. In an area exposed to dripping water or outside weather conditions. 2. In an area where it will come in contact with curtains, drapes, or anything that will obstruct the flow of combustion and ventilation air.
  • Page 5: Mobile Home Installation

    MOBILE HOME INSTALLATION 1. Dryer MUST be exhausted outside (outdoors, not beneath the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred. 2.
  • Page 6: Unpacking

    TOP CONSOLE MODELS ROUGH-IN DIMENSIONS ROUGH-IN DIMENSIONS ROUGH-IN DIMENSIONS ROUGH-IN DIMENSIONS ROUGH-IN DIMENSIONS (68.3 cm) (68.3 cm) (68.3 cm) (68.3 cm) (68.3 cm) ELECTRIC CONNECTION ELECTRIC CONNECTION ELECTRIC CONNECTION ELECTRIC CONNECTION ELECTRIC CONNECTION (6.5 cm) (6.5 cm) (6.5 cm) (6.5 cm) (6.5 cm) 13 1/2"...
  • Page 7: Electrical Installation

    ELECTRICAL INSTALLATION ALL ELECTRIC Dryers The following are specific requirements for proper and safe electrical installation of your dryer. Failure to follow these instructions can create electrical shock and/or a fire hazard. This appliance MUST be properly grounded. Electrical shock can result if the dryer is not properly grounded.
  • Page 8: Electrical Connections

    GREEN GROUND SCREW GREEN NEUTRAL GROUND WIRE STRAIN RELIEF MOUNTING BRACKET ELECTRICAL CONNECTIONS FOR 3-WIRE SYSTEM Non-Canadian ELECTRIC Dryer 1. Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner. 2.
  • Page 9: Installation

    INSTALLATION 1. GAS CONNECTION (Gas dryers only) a. Remove the shipping cap from gas pipe at the rear of the dryer. NOTE: DO NOT connect the dryer to L.P. gas service without converting the gas valve. An L.P. conversion kit must be installed by a qualified gas technician.

Table of Contents