ESC iXi2 Specify command mode

[ASCII]
ESC i X i 2 n1 n2 n3
[Decimal]
27 105 88 105 50 nd1 nd2 nd3
[Hexadecimal]
1B 69 58 69 32 nh1 nh2 nh3
[Parameters]
nh1:01h (Fixed)
nh2:00h (Fixed)
nh3:00h 01h 03h
[Description]
·
Switches the mode.
nh3=00h: ESC/P mode (default)
nh3=01h: Raster mode
nh3=03h: P-touch Template mode
·
This command is a static command.
[Remarks]
Invalid when the specified value is any other than those that can be set