Calibration:voltage - HP E8402A User And Service Manual

Vxi c-size mainframe
Table of Contents

CALibration:VOLTage?

Returned Data
Comments
Error Conditions
Reset Condition
Related
Commands
204 Calibrating and Verifying Performance
CALibration:VOLTage?
Calibrations performed are: Calculate A/D offset and gain for each VXI supply.
Externally measured voltages previously reported to the enhanced monitor through
CAL:VAL:VOLT are used for these calculations.
Type
Range
int16
0-32767
Make the calibration values measurements and provide them to the enhanced
monitor via the CAL:VAL:VOLT command immediately prior to using this
command. Old values will be used otherwise.
The calibration values (reported to the enhanced monitor with
CAL:VAL:VOLT) have default values that will be used by the calibration
routines if no values are ever measured and reported to the enhanced monitor.
See CAL:VAL:VOLT for details.
The following table lists the most common error conditions and causes. Error
numbers and corresponding messages can be found using SYSTem:ERRor? query.
Number
Message
-221
"Settings Conflict" The mainframe's power is off.
-410
Query interrupted
Calibration is not affected by reset. However, if a *RST is issued while a calibration
is occurring the calibration will be aborted.
CALibration:TEMPerature?
performs the voltage-related calibration procedures.
+0 indicates a satisfactory calibration.
+1096: bad voltage gain calculation on +5V Supply
+1097: bad voltage gain calculation on +12V Supply
+1098: bad voltage gain calculation on -12V Supply
+1099: bad voltage gain calculation on +24V Supply
+1100: bad voltage gain calculation on -24V Supply
+1101: bad voltage gain calculation on -5.2V Supply
+1102: bad voltage gain calculation on -2V Supply
Calibration was aborted by a device clear event, or a *RST
Description
Probable Cause
Chapter 4
Table of Contents
loading