Miele H 399 B Installation Instructions Manual
Miele H 399 B Installation Instructions Manual

Miele H 399 B Installation Instructions Manual

Hide thumbs Also See for H 399 B:

Installation instructions

Oven
H 399 B
GiZr
To avoid the risk of accidents
or damage to the appliance
it is essential to read these
instructions before it is installed
or used for the first time.
M.-Nr. 05 741 720
loading

Summary of Contents for Miele H 399 B

  • Page 1: Installation Instructions

    Installation instructions Oven H 399 B GiZr To avoid the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed or used for the first time. M.-Nr. 05 741 720...
  • Page 2: Table Of Contents

    H 399 B ........
  • Page 3: General Notes

    General notes Installation Keep these instructions in a safe place and pass them on to any future owner This equipment is not designed for of the appliance. maritime use or for use in mobile installations such as caravans, aircraft All dimensions in this instruction booklet etc.
  • Page 4: Appliance And Building-In Dimensions

    H 399 B Appliance and building-in dimensions 5 4 0 8 4 5 5 4 0 8 4 5...
  • Page 5: Building In And Connecting To Services

    Cover panel, behind which the termi- nals in the appliance are located. h Filler strip HAL 90 Filler strip h is only required when fitting an H 399 B into a base unit. It is available to order through the Spare Parts Dept.
  • Page 6: Securing The Oven

    H 399 B Securing the oven After it has been aligned the oven must be secured in the housing unit. ^ Fit the fixing screws j (supplied) into the vertical strip on the left hand side of the appliance as shown in the illus- tration.
  • Page 7: Electrical Connection

    Electrical connection Electrical connection UK/ZA Connection of this appliance should be made via a suitable isolator which com- All electrical work should be under- plies with national and local regulations taken by a suitably qualified and and the on/off switch should be easily competent person in strict accor- accessible after the appliance has dance with national and local safety...
  • Page 8 Electrical connection Important U.K. This appliance is designed for connec- tion to a single phase 230-240 V 50 Hz supply using a suitable 3-core cable. The wires in the mains lead are col- oured in accordance with the following code: Green/yellow = earth Blue = neutral...
  • Page 9: Connection Diagram

    Electrical connection Connection diagram Important The electrical safety of this appliance can only be guaranteed when continu- ity is complete between the appliance and an effective earthing system, which complies with local and national regula- tions. It is most important that this basic safety requirement is tested by a quali- fied electrician.
  • Page 12 Alteration rights reserved / M.-Nr. 05 741 720 / V03 This paper consists of cellulose which has been bleached without the use of chlorine.