Honeywell T8524 Deluxe Product Data
Honeywell T8524 Deluxe Product Data

Honeywell T8524 Deluxe Product Data

Deluxe electronic thermostat
T8524 Deluxe Electronic Thermostat

APPLICATION

The T8524 Deluxe Electronic Thermostat provides electronic
control of 18 to 30 Vac multistage heating and cooling systems.
® U.S. Registered Trademark
Copyright © 1997 Honeywell Inc. •

T8524 FEATURES AND BENEFITS

• Attractive styling complements any decor to the
• Ease-of-use means fewer homeowner questions and
• Back lighting the large display makes the Liquid
• Most frequently used keys are located by the LCD for
• Models available with outdoor temperature sensor
• Configurable features allows one model to be used to
• Minimum off time for cooling compressors and heat
• Easy installation, setup and system test saves
• System test simplifies troubleshooting and saves time
• Setpoints are permanently held in memory (no
Application ........................................................................... 1
T8524 Features and Benefits .............................................. 1
Specifications ...................................................................... 2
Ordering Information ........................................................... 2
Installation ........................................................................... 3
Wiring .................................................................................. 4
Settings ............................................................................... 6
Installer Setup ..................................................................... 6
Installer System Test ........................................................... 8
Checkout ............................................................................. 10
Operation ............................................................................ 11
Wiring Diagram (Fig. 14) ..................................................... 12
Troubleshooting Guide ........................................................ 12
• All Rights Reserved
homeowner's delight.
increased homeowner satisfaction.
Crystal Display (LCD) very easy to read.
quick and easy access to information.
capability for homeowner convenience. The sensor is
also more accurate than a thermometer.
replace many different models (less inventory, no need
to carry separate models to get these features).
- °F or °C temperature display;
- automatic or manual changeover;
- electric or conventional heat fan operation;
- adjustable heating cycle rate.
pumps protects and extends the life of the equipment.
installer time and increases productivity.
by overriding the time delays.
batteries used) and retained during power outages for
increased installer and homeowner convenience.
PRODUCT DATA
Contents
68-0202
Table of Contents
loading

Summary of Contents for Honeywell T8524 Deluxe

  • Page 1: Table Of Contents

    • Easy installation, setup and system test saves installer time and increases productivity. The T8524 Deluxe Electronic Thermostat provides electronic control of 18 to 30 Vac multistage heating and cooling systems. • System test simplifies troubleshooting and saves time by overriding the time delays.
  • Page 2: Specifications

    Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
  • Page 3: Installation

    T8524 DELUXE ELECTRONIC THERMOSTAT Operating Ambient Temperature: INSTALLATION 40°F to 110*F (4°C to 43°C). When Installing this Product... Shipping Temperature Range: Minus 20°F or 130°F (-29°C to 54°C). 1. Read these instructions carefully. Failure to follow the instructions can damage the product or cause a Operating Relative Humidity Range: hazardous condition.
  • Page 4: Wiring

    T8524 DELUXE ELECTRONIC THERMOSTAT 5 FEET [1.5 METERS] M10106 Fig. 2. Typical location of thermostat. 2. Use a pencil to mark the mounting holes. See Fig. 3. WIRING 3. Remove the wallplate from the wall and drill two 3/16 inch holes in the wall (if drywall) as marked. For firmer...
  • Page 5: Mounting Thermostat

    T8524 DELUXE ELECTRONIC THERMOSTAT Mounting Thermostat CAUTION 1. Engage tabs at the top of thermostat and wallplate. Disconnect power before wiring to prevent electrical Fig. 5. shock or equipment damage. 2. Press lower edge of case to latch. 1. Loosen the terminal screws on the back of the NOTE: To remove the thermostat from the wall, first pull out thermostat and connect the system wires.
  • Page 6: Settings

    T8524 DELUXE ELECTRONIC THERMOSTAT SETTINGS A combination of key presses are required to use the Installer Setup feature. — To enter the Installer Setup, press and hold the System and Fan Settings Information i key with the increase and decrease keys until the first number is displayed.
  • Page 7 T8524 DELUXE ELECTRONIC THERMOSTAT Table 4. Thermostat Installer Setup Options. Installer Setup Number (Press Other Choices Time key to Factory-Setting (Press key to change) Actual Select change) Display Description Display Description Setting Not used — — — — — Fan operation...
  • Page 8: Installer System Test

    T8524 DELUXE ELECTRONIC THERMOSTAT Table 4. Thermostat Installer Setup Options (continued). Installer Setup Number (Press Other Choices Time key to Factory-Setting (Press key to change) Actual Select change) Display Description Display Description Setting Temperature range Lowest setpoint 46 to 99 Temperature range (1°F...
  • Page 9 T8524 DELUXE ELECTRONIC THERMOSTAT Table 5. Tests Available in the Installer System Test. Test Number System Test Description 10-19 Heating equipment can be turned on and off 30-39 Cooling equipment can be turned on and off 40-49 Fan equipment can be turned on and off.
  • Page 10: Checkout

    T8524 DELUXE ELECTRONIC THERMOSTAT 5. Press the increase key again to display the EEPROM Thermostat Information identification code. 1. Press the Information i key to access the thermostat (Example: 222 = EEPROM ID 222). information. M4867 M4864 6. Press and hold the increase...
  • Page 11: Operation

    T8524 DELUXE ELECTRONIC THERMOSTAT OPERATION Operation Sequence The thermostat energizes specific terminals depending what the Fan and System are set to. The LCD will display the time, P+I Control room temperature, system and fan selection. symbols will be The thermostat microprocessor based control requires that displayed when the heating, cooling or fan is energized.
  • Page 12: Wiring Diagram (Fig. 14)

    T8524 DELUXE ELECTRONIC THERMOSTAT WIRING DIAGRAM (Fig. 14) Minimum-Off Timing A minimum-off timer assures that the cooling compressor or THERMOSTAT heat pump compressor does not come on again for at least five minutes after it turns off. The minimum-off timer is triggered when the compressor goes off and when the system switch is changed.
  • Page 13 T8524 DELUXE ELECTRONIC THERMOSTAT Symptom Possible Cause Action The upper or lower Check the temperature setpoints: Temperature settings will temperature limits were • Heating limits are 45°F to 88°F (7°C to 31°C) not change. (Example: reached. • Cooling limits are 48°F to 99°F (9°C to 37°C).
  • Page 14 T8524 DELUXE ELECTRONIC THERMOSTAT 68-0202...
  • Page 15 T8524 DELUXE ELECTRONIC THERMOSTAT 68-0202...
  • Page 16 T8524 DELUXE ELECTRONIC THERMOSTAT Home and Building Control Home and Building Control Honeywell Asia Pacific Inc. Honeywell Inc. Honeywell Limited-Honeywell Limitée Room 3213-3225 Honeywell Plaza 155 Gordon Baker Road Sun Hung Kai Centre P.O. Box 524 North York, Ontario No. 30 Harbour Road...