Fujitsu Inverter ABTG54LR Operating Manual
Fujitsu Inverter ABTG54LR Operating Manual

Fujitsu Inverter ABTG54LR Operating Manual

Air conditioner ceiling suspension type indoor unit

Quick Links

AIR CONDITIONER
Ceiling Suspension Type
Indoor Unit
ABTG54LR
KEEP THIS MANUAL FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED

OPERATING MANUAL

PART NO. 9374379576
Table of Contents
loading

Summary of Contents for Fujitsu Inverter ABTG54LR

  • Page 1: Operating Manual

    OPERATING MANUAL AIR CONDITIONER Ceiling Suspension Type Indoor Unit ABTG54LR KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED PART NO. 9374379576...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ........2 SWING OPERATION ........... 12 FEATURES AND FUNCTIONS ......3 ECONOMY OPERATION ........12 NAME OF PARTS ..........4 10 °C HEAT OPERATION ........13 PREPARATION ............6 SELECTING THE REMOTE OPERATION ............7 CONTROLLER SIGNAL CODE ......13 TIMER OPERATION ..........
  • Page 3: Features And Functions

    SAFETY PRECAUTIONS This appliance is not intended for use by persons (including children) with reduced CAUTION physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 4: Name Of Parts

    NAME OF PARTS Indoor unit 1 Operating control panel 2 MANUAL AUTO button When the MANUAL AUTO button is pressed in for more than 10 seconds, the forced cooling operation will start. The forced cooling operation is used at the time of installation.
  • Page 5: Remote Controller

    NAME OF PARTS Remote controller Display panel Display panel To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actual oper- ation, however, the display will only show those indicators appropriate to the current operation. 1 MODE button F Signal transmitter 2 10 °C HEAT button...
  • Page 6: Preparation

    PREPARATION CAUTION Turn on the Power Take care to prevent infants from acciden- tally swallowing batteries. Turn on the circuit breaker. When not using the remote controller for an extended period, remove the batteries to avoid possible leakage and damage to the Load Batteries (AAA/R03/LR03 ×...
  • Page 7: Operation

    OPERATION To Select Mode Operation Press the START/STOP button. The indoor unit’s OPERATION indicator lamp (green) will light. The air conditioner will start operating. Press the MODE button to select the desired mode. Each time the button is pressed, the mode will change in the following order. AUTO COOL HEAT...
  • Page 8 OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Stop Operation Press the START/STOP button. The OPERATION indicator lamp (green) will go out. Mode Operation AUTO (in COOLING model): When AUTO (automatic changeover) operation first selected, the fan will operate at very low speed for about a few minutes, during which time the indoor unit detects the room conditions and selects the proper mode.
  • Page 9: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the remote controller is set to the correct current time ( Page 6). If the indoor unit is connected to a wired remote controller, the wireless remote controller cannot be used to set the timer. To Use the ON Timer or OFF Timer Press the START/STOP button To Cancel the Timer...
  • Page 10: Sleep Timer Operation

    SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. If the indoor unit is connected to a wired remote controller, the wireless remote controller cannot be used to set the sleep timer. To Use the SLEEP Timer To Cancel the Timer While the air conditioner is operating or stopped, press the...
  • Page 11: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Adjust the up, down, left and right air directions with the air direction buttons on the remote controller. Use the air direction buttons after the indoor unit has started operating and the airflow-direction louvers have stopped moving. Vertical Air Direction Adjustment DANGER Press the SET button (Vertical).
  • Page 12: Swing Operation

    SWING OPERATION Begin air conditioner operation before performing this procedure. To select SWING Operation Press the SWING button. Each time the SWING button is pressed, the swing operation will change in the following order. Up/down swing operation Left/right swing operation Swing operation stops Up/down/left/right swing operation To stop SWING Operation...
  • Page 13: 10 °C Heat Operation

    10 °C HEAT OPERATION While 10 °C HEAT operation is in To use 10 °C HEAT Operation progress, only the following operation can be used. Press the 10 °C HEAT button. • SWING The OPERATION indicator lamp (green) will go out, and the ECONOMY indicator lamp (green) will light.
  • Page 14: Cleaning And Care

    CLEANING AND CARE Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply. CAUTION Turn off the electrical breaker. When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the power WARNING supply plug or turn off the circuit breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
  • Page 16: Operating Tips

    TROUBLESHOOTING Symptom Problem See page CHECK ONCE Does not operate at all: Has the circuit breaker been turned off? MORE Has there been a power failure? — Has a fuse blown out, or a circuit breaker been tripped? Is the timer operating? 9 to 10 Poor cooling (or heating*) Is the air filter dirty?
  • Page 17: Auto Restart

    OPERATING TIPS AUTO Restart In Event of Power Interruption Should the power supply to the air conditioner be interrupted Use of other electrical appliances (electric shaver, etc.) or by a power failure, the air conditioner will restart automatically nearby use of a wireless radio transmitter may cause the air in the previously selected mode once the power is restored.