INSTALLATION
AND SERVICE
MUST BE PERFORMED
BY A QUALIFIED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL
ELECTRICAL
INSPECTOR'S
USE.
READ AND SAVE THESE
INSTRUCTIONS
FOR FUTURE
REFERENCE.
Clearances and Dimensions
1.
Provide adeauate clearances between the range and adjacent combustiblesurfaces.
2.
LocationmChecklocationwhere the ranae will be installed. Check for properelectrical supply, and the stability ofthe floor.
3.
Dimensionsthat are shown must be used. Given dimensions )rovide minimum clearance. Contact surface must be solid and level.
RANGE
RANGEELECTRICAL
FRONT
TYPICALCABINETINSTALLATION
SIDE
OVERALL
CONNECTIONS
_
VIEW
DIMENSIONS
29 1/4" with
_AIIdimensionsfor
door handle
I electricaloutlet location I
' "
30"
25-3/4"
jA.are
maximum,
j
30"
...... _
_u°--*'%'
_
zji
:_-':'--m.
Minimum*
_,o1: _to.13
i
I __j--_"-J['Dashedcubedarea
1
-_ _-
wall on either
18" cabinetson
Maximumdepth
side of range
eitherside
for cabinets
[_CentedineI showswhere the
l
®®
of range.
ma
um
above 36" height.
of range I electricaloutlet must |
l
above rangetop.
|
!
I be installedfor flush )1
........................................................................
_
,__
_--
I..,
11.. Lthe wall installation, j
1_
_25,!
_
I
II
36 + 1/8"
_:_
I
door open
"\\_29-7/8"
_
--
" < -_
Edge
maximum
_ _ _ _"
2-5/8"for models equipped
_
_ _ _
withwarmer drawers.
_
3-1/2"for models equipped
Fig.
1
with storagedrawers
Fig.
2
Fig.
3
_'_
30"
_
0" clearancebelow cookingtop and at rearof range.
*30" MINIMUMCLEARANCE BETWEENTHE TOP OF THE COOKINGSURFACE AND THE BOTTOMOF AN UNPROTECTEDWOOD OR
METAL CABINET;OR24" MINIMUMWHEN BOTTOM OFWOOD OR METAL CABINET ISPROTECTEDBY NOT LESSTHAN 1/4" FLAME
RETARDANTMILLBOARD COVEREDWITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015" STAINLESSSTEEL, 0.024"ALUMINUM OR
0.020"COPPER. 0" CLEARANCE ISTHE MINIMUMFOR THE REAR OF THE RANGE. FOLLOWALL DIMENSION REQUIREMENTSPROVIDED
ABOVE TO PREVENTPROPERTY DAMAGE,POTENTIALFIREHAZARD,AND INCORRECTCOUNTERTOPAND CABINET CUTS.
TO ELIMINATE THE RISKOFBURNSORFIREBYREACHING OVERHEATEDSURFACEUNITS,CABINETSTORAGESPACELOCATEDABOVE
THESURFACEUNITSSHOULDBEAVOIDED.IFCABINETSTORAGEIS TO BEPROVIDED, T HERISKCANBEREDUCEDBYINSTALLINGA
RANGEHOODTHAT PROJECTSHORIZONTALLYA MINIMUMOF5"BEYONDTHE Bo'n'OM OFTHECABINETS.
IMPORTANT SAFETY INSTRUCTIONS
_
Tip Over Hazard
• A child or adult can tip the range and
be killed.
• Verify the anti-tip device has been
installed to floor or wall.
• Ensure the anti-tip device is re-engaged when the range
is moved to floor or wall.
• Do not operate the range without the anti-tip device in
place and engaged.
• Failure to follow these instructions can result in death or
serious burns to children and adults.
_J_i
Range
leveling leg
)_o'__, :,] ^_+=_-=_
_
-_/i/_ ,-,.u--.t-,
__jJ
bracket
To check if the anti-tip bracket is installed properly, use both
arms and grasp the rear edge of range back. Carefully
attempt to tilt range forward. When properly installed, the
range should not tilt forward.
Refer to the anti-tip bracket installation
instructions
supplied with your range for proper installation.
If the information in this manual is not followed
exactly, a fire or electrical shock may result causing property
damage, personal injury or death.
Important Notes to the Installer:
•
Read all instructions contained in these installation
instructions before installing range.
•
Remove all packing material from the oven compartments
before connecting the gas & electrical supply to the range.
•
Observe all governing codes and ordinances.
•
Be sure to leave these instructions with the consumer.
Important Notes to the Consumer:
Keep these instructions with your owner's guide for future
reference.
•
As when using any appliance generating heat, there are
certain safety precautions you should follow. These are
listed in the Use & Care Guide, read it carefully.
•
Be sure your range is installed and grounded properly by a
qualified installer or service technician.
•
Make sure the wall coverings around the range can
withstand the heat generated by the range.
•
To eliminate the need to reach over the surface elements,
cabinet storage space above the elements should be
avoided.
pin 316454912 rev C
Espa_ol - Paginas 5-8