Using Fabric Manager
GBIC Distance
Indicates the length of the fibre channel link, which
can be long distance, intermediate distance, or short
distance.
Encoding
Indicates the serial encoding mechanism, which can
be 8B10B, 4B5B, NRZ, or Manchester.
Baud Rate
Nominal baud rate in units of 100 Megabyte.
BR Max
Upper limit at which GBIC meets its specifications (in
units of 1% above nominal baud rate).
BR Min
Lower limit at which GBIC meets its specifications
(in units of 1% below nominal baud rate).
Options
Can indicate any of the following:
• Loss of Signal
• Loss of Signal Inverted
• Transmission Fault
• Transmission Disable
Length 9u
Length of link using single-mode fibre.
Length 50u
Length of link using 50um multi-mode fibre.
Length 625u
Length of link using 62.5um multi-mode fibre.
Vendor Name
Name of vendor.
Vendor OUI
Unique identifier for vendor.
Vendor P/N
Vendor part number.
Vendor Rev
Vendor revision number.
Serial No.
Vendor serial number.
Date Code
Vendor date code.