Table of Contents
Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
8742
Pinned track(s) exists in the primary data
volume.
6505
8743
Pinned track(s) exists in the secondary
data volume.
6505
8744
The specified primary data volume
cannot be used.
6505
8745
The secondary data volume is already
in use by another system.
6505
8746
The emulation type of the primary data
volume is not supported by Continuous
Access Journal or Continuous Access
Journal Z.
6505
8749
The specified secondary data volume is
online.
6505
8753
An internal error occurred.
6505
8757
One side of the cache or the shared
memory is blocked in the primary
storage system.
Recommended Action
Check the status of the pinned tracks in
the primary data volume, and clear the
pinned tracks.
Check the status of the pinned tracks in
the secondary data volume, and clear
the pinned tracks.
Check whether the primary data volume
is in any of the following conditions:
Data in the primary data volume is
being copied; correction copy or
drive copy is in progress.
The primary data volume is in
correction access condition.
The primary data volume is blocked.
The primary data volume is being
maintained.
The access attribute of the primary
data volume is Read Only.
Check whether the secondary data
volume in the remote storage system,
which are connected from hosts or the
SVP, is in any of the following
conditions:
The secondary data volume is being
used by Dual Copy.
The secondary data volume is being
used by XRC Replication.
The secondary data volume is being
used by PPRC or Remote Copy.
The secondary data volume is being
used by Concurrent Copy.
The access attribute of the secondary
data volume is Read Only.
See the INSTALLATION SECTION and
the OPENPLATFORM SECTION in the
maintenance manual to check if the
device emulation of the primary data
volume is supported.
Check if the secondary data volume is
online. If the secondary data volume is
online, vary the volume offline, then retry
the operation. If the secondary data
volume is connected to a VM system,
vary the volume offline from the VM
system.
Check the SSB log, then contact HP
Technical Support.
Check the status of the cache and the
shared memory in the primary storage
system.
Ensure that the cache and shared
memory is not blocked.
Severity
Level
W
W
W
W
W
W
E
E
Part code 6505 169