Frigidaire FGBD2432KB Service Data Sheet page 2

Electronic series
Hide thumbs Also See for FGBD2432KB:
Color Code
BK......................... Black
BU............................Blue
PK............................Pink
R...............................Red
R-BK...............Red/Black
R-Y................Red/Yellow
VIO.........................Violet
W...........................White
Water/Service Test
The water/service test is a special function
initiated from the power failure mode or idle
mode.
While in power failure or idle mode -
simultaneously press the NO HEAT DRY and
START/CANCEL pads for 1 1/2 seconds.
The dishwasher will then step through the test
cycle per the chart. Pushing the START/CANCEL
pad will advance the dishwasher to the next step.
Operation
LO
.........Low liquid in the rinse aid dispenser
PF
..........A power failure has occurred
Hd or HO
CL
..........Close and latch the door
'01-24'
(Some models)
'01-10'....Hour(s) delay before start
(Some models)
Cycle Selection Options
Display Codes (Readout)
SENSING
WASHING
.........Water heating delay
SANITIZED
DRYING
CLEAN
....Hour(s) delay before start
OPTION LED's Flashing
STATUS LED's Flashing
RINSE AGENT LOW ------- The liquid rinse agent is low. Light will switch off after 5 complete wash cycles or dispenser is filled.
(Some models)
Wiring Diagram
Display Codes (LED)
---------------------- Turbidity sensor is checking the condition of the wash/rinse water.
No sensing for LIGHT WASH (UPPER RACK), LIGHT WASH (LOWER RACK) and CHINA/CRYSTAL.
---------------------- Wash portion of cycle.
-------------------- The SANITIZED criteria has been met. Indicator light will switch off when door is opened.
------------------------ Drying portion of cycle.
------------------------ Shows completion of cycle. Indicator light will switch off when door is opened.
-- HI-TEMP WASH and NO HEAT DRY/POWER DRY OFF LED's flashing indicates power failure has
occurred. Press START/CANCEL pad and reselect desired options and cycle.
-- The STATUS LED's that are lit when the door is opened will flash. Close door.
*TURBIDITY SENSOR/
THERMISTOR
loading