Wiring Power Supply And Grounding Cable; Wiring Reset Signal - Omron V670 Series User Manual

Electromagnetic inductive rfid system
Hide thumbs Also See for V670 Series:
Table of Contents
3-1 Controller

3-1-6-1 Wiring Power Supply and Grounding Cable

(Example of Wiring)
+DC24V
M3 self-up screws are used for the power supply and ground terminal. For a crimp terminal, use any of terminals below. Tightening
torque should be approximately 0.6 N•m.
♦ Applicable crimp terminal
Manufacturer
Japan Solderless
1.25-N3A
Terminal
Japan Solderless
1.25-Y3A
Terminal
♦ Recommendable DC power supply (small-sized) (OMRON)
Model
S82K-03024
S82J-0224
* Rated power consumption of the controller is 24VDC and 0.2 A (7 W). Decide the capacity taking into consideration inrush current
(approximately 5 A).

3-1-6-2 Wiring Reset Signal

3-10
0V
Model
Applicable Wire
AWG24 to
AWG16
Output Capacity
24 VDC 1.3 A
24 VDC 1.1 A
24VDC
V 6 7 0 - CD1 D
V670-CD1D-V1
ID
Ferrite core
(attached to the product)
Grounding of Class D
Type
Fork
V 6 7 0 - CD1 D
V670-CD1D-V1
ID
RST
OUT1
OUT2
O.COM
/IN
Reset Input
(For M3)
Input Voltage
100/200 VAC
100 VAC
Table of Contents