Quick Links

As part of Paradyne's ongoing enhancement and quality program, the COMSPHERE
3600 Series Data Service Unit (DSU) incorporates several new features. Firmware and
DSUs with firmware releases 8.xx and above provide:
Automatic detection of the DDS data rate. The factory-default for Rate(Kbps) is now
Auto. For maximum reliability and minimum power-up time, set the actual data rate
after installation.
Two additional factory default configuration sets are available for multipoint control
and multipoint tributary.
Each set of existing factory default configuration options has changed. Refer to
Table A-1 in Appendix A in each of the following documents:
3610-A2-GB46
3610-A2-GB48
3610-A2-GB49
When any change is made to a configuration and not saved, a prompt displays
asking the user: Save Options? or Save Changes?
Dial Tone Test is available from the Test branch for Dial Backup Modules (DBMs).
Reset is available from the Control branch to initiate a power-up routine.
Power On Test General configuration option. When disabled, the DSU bypasses
device tests.
Facility Alarms for crossed pair detection, no synchronization during auto-rating,
control mode idle, and rate conflict.
New Revision to COMSPHERE 3600 Series Product-Related Documentation
Document Name
COMSPHERE 3600 Series Data Service
Units, Models 3610 and 3611, User's Guide
COMSPHERE 3600 Series Data Service
Units, Models 3610 and 3611, Time Division
Multiplexer, Multichannel Multipoint, and
Digital Bridge Options Supplement
COMSPHERE 3600 Series Data Service
Units, Models 3610 and 3611, Dial Backup
Module Options Supplement
COMSPHERE 3000 Series Carrier,
Installation Manual
Document No. 3610-A2-GK40-22
** SPECIAL NOTICE **
Number
3610-A2-GB46
3610-A2-GB48
3610-A2-GB49
3000-A2-GA31
TM
March 1997
Description
Ships with all standalone
3610 DSUs.
Supplement to the User's Guide.
Ships with Model 3610 DSUs with
MCMP/TDM options or upgrades.
Supplement to the User's Guide.
Ships with Model 3610 DSUs with
Dial Backup Module (DBM) options
or upgrades.
Ships with every carrier.
Page 1 of 2
loading

Summary of Contents for Paradyne 3000

  • Page 1 Units, Models 3610 and 3611, Time Division Multiplexer, Multichannel Multipoint, and Digital Bridge Options Supplement COMSPHERE 3600 Series Data Service Units, Models 3610 and 3611, Dial Backup Module Options Supplement COMSPHERE 3000 Series Carrier, Installation Manual Document No. 3610-A2-GK40-22 Number Description 3610-A2-GB46 Ships with all standalone 3610 DSUs.
  • Page 2 ** SPECIAL NOTICE (continued) ** Software and Firmware Version Control The DSU software version now has an additional setting of 6.66. Use the new setting of 6.66 when the control DSU firmware version is 5.00 to 6.99 and the tributary DSU firmware version is 7.25 or higher.

This manual is also suitable for:

36103611Comsphere 3600 series