EN - english Instructions for installation and operation Compressed air refrigeration dryer ® DRYPOINT RAC 10-480 NA...
Page 2
Dear customer, ® Thank you for deciding in favour of the DRYPOINT RAC 10-480 NA compressed-air refrigeration dryer. Please read ® these installation and operating instructions carefully before mounting and starting up the DRYPOINT RAC 10-480 NA ® and follow our directions. Perfect functioning of the DRYPOINT RAC 10-480 NA and thus reliable compressed-air drying can only be guaranteed when the provisions and notes stipulated here are strictly adhered to.
Contents Name plate Safety instructions Safety pictograms in accordance with DIN 4844 Signal words in accordance with ANSI Overview of the safety instructions Proper use Exclusion from a field of application ...
Page 4
13.3.5 Electric diagram DRYPOINT RAC 300 NA 13.3.6 Electric diagram DRYPOINT RAC 375 NA 13.3.7 Electric diagram DRYPOINT RAC 480 NA Pos: 1 /Beko Technische Dokumentation/Überschriften/1/Sicherheitshinweise @ 0\mod_1183637609261_6.doc @ 5365 DRYPOINT® RAC 10-480 NA...
This manual must be available at all times for future reference and is a constituent part of the dryer. If you have any queries regarding these installation and operating instructions, please contact BEKO TECHNOLOGIES GMBH.
Do not operate with open cover (housing) Maintenance works or controlling measures must only be carried out by qualified personnel Do not smoke Note Pos: 4 /Beko Technische Dokumentation/Sicherheit/Gefahr Druckluft @ 0\mod_1184148143854_6.doc @ 577 ARIA Connection point compressed-air inlet LUFT...
Page 7
Safety instructions Works can be carried out by the operator of the plant, provided that they are skilled accordingly NOTE: Text that contains important specifications to be considered – does not refer to safety precautions. The device was carefully designed with particular attention paid to environmental protection: ...
Make sure that the power supply is switched off and that the device is off and marked for maintenance measures. Please also ensure that the power supply cannot be re-established during the works. Pos: 7 /Beko Technische Dokumentation/Sicherheit/Maßnahmen Netzspannung BM 31/32/33 @ 0\mod_1216898430699_6.doc @ 11319 Caution! Refrigerant! The compressed-air refrigeration dryer uses HFC-containing refrigerants as a coolant.
Page 9
Safety instructions Warning! Refrigerant leak! A refrigerant leak involves the danger of serious injury and damage to the environment. ® The DRYPOINT RAC 10-480 NA compressed-air refrigeration dryer contains fluorinated greenhouse gas/refrigerant. Installation, repair and maintenance works at the refrigeration system must only be carried out by certified skilled personnel (specialists).
Page 10
Operators of the devices must observe the local and national pressure equipment regulations in the country of installation. Pos: 8 /Beko Technische Dokumentation/Sicherheit/Sicherheitshinweise, weitere BM (nicht Ex) @ 0\mod_1183616103770_6.doc @ 4009os: 9 /Beko Technische Dokumentation/Sicherheit/Zusatz Sicherheitshinweise BM33 @ 0\mod_1231926887620_6.doc @ 12829s: 10 /Beko Technische Dokumentation/Sicherheit/Vorsicht Fehlfunktion @ 0\mod_1214378096290_6.doc @ 9359 Note!
This dryer is not suitable for the treatment of contaminated air or of air containing solids. Pos: 16 /Beko Technische Dokumentation/Bestimmungsgemäße Verwendung/BEKOMAT/Ausschluß Anwendung BM 31/32/33 @ 0\mod_1236003837511_6.doc @ 13736 Operating instructions in accordance with the 97/23/EC Pressure Equipment Directive The DRYPOINT®...
Transport Transport Check the packaging for visible loss or damage. If no visible damage can be ascertained, place the unit in close proximity to the place of installation and unpack the device. During this procedure, the dryer must always remain in an upright position. The components may be damaged when the unit is tilted or turned upside down.
Installation Installation Place of installation Note! Ambient conditions! In the event that the dryer is not installed under suitable ambient conditions, the ability of the device to condense refrigerant gas is impaired. This can result in a higher load of the refrigerating compressor, and in a loss of efficiency and performance of the dryer.
Installation Installation plan - A - Air compressor Aftercooler Condensate separator Prefilter Bypass group Dryer Compressed-air tank - B - Final filter Bekomat condensate drain Installation type A is recommended when the total consumption corresponds to the throughput rate of the compressor. Installation type B is recommended when the air consumption constantly varies, with peak values which considerably exceed the throughput rate of the compressor.
Installation Connection to the compressed-air system Danger! Compressed air! All works must only be carried out by qualified skilled personnel. Never work on compressed-air systems which are under pressure. The operator or the user must ensure that the dryer is never operated with a pressure exceeding the maximum pressure value indicated on the name plate.
Start-up Start-up Preliminary stages Note! Exceeding of the operating parameters! Ensure that the operating parameters comply with the nominal values indicated on the name plate of the dryer (voltage, frequency, air pressure, air temperature, ambient temperature etc.). Prior to delivery, this dryer was thoroughly tested, packed and checked. Please verify the soundness of the dryer during the initial start-up and check the perfect functioning during the first operating hours.
Start-up Shut down and restart Shut down (see Section 11.1 "Control panel") • Ensure that the dew point temperature indicated on the electronic control unit is stable. • Interrupt the compressed-air supply. • After a few minutes, stop the dryer by switching off the main switch on the control panel (pos. 1). Restart (see Section 11.1 "Control panel") •...
Technical description 11 Technical description 11.1 Control panel The control panel explained below is the only dryer user interface. RAC 10 – 175 DMC15 sec - min RAC 220 – 480 DMC15 sec - min ON-OFF Switch Electronic instrument Air and refrigerant flow diagram 11.2 Functional description Operating principle –...
Technical description 11.4 Refrigerating compressor The employed refrigerating compressors are constructed by leading manufacturers. The hermetically sealed construction is absolutely gastight. The integrated safeguard protects the compressor against overheating and excess current. The protection is automatically reset as soon as the nominal conditions are reached again. 11.5 Condenser The condenser is the component in which the gas coming from the compressor is cooled down, condensed and liquefied.
Technical description 11.10 Refrigerant pressure switches LPS – HPS – PV To ensure the operational reliability and the protection of the dryer, a series of pressure switches are installed in the gas cycle. LPS : Low-pressure guard on the suction side of the compressor, which is triggered when the pressure drops below the predetermined value.
Technical description 11.12 DMC 15 electronics (control unit compressed-air dryer) Led – Power ON DMC15 Led - Drain ON Led – Condenser fan ON (RAC 10-100) sec - min Button – Setup menu access Button – Increase / Drain test DISPLAY The DMC15 displays DewPoint temperature, controls the condenser fan activation and the timed drainer.
Technical description 11.12.4 Control of the condenser fan (RAC 10-100) A temperature probe T2 is located on the discharge side of the condenser. The condenser fan is activated (ON) when the T2 temperature is higher than FANon setting (standard 35°C / 96°F) and led is ON.
Maintenance, troubleshooting, spare parts and dismantling 12 Maintenance, troubleshooting, spare parts and dismantling 12.1 Checks and maintenance Certified skilled personnel Installation works must exclusively be carried out by authorised and qualified skilled personnel. Prior to ® undertaking any measures on the DRYPOINT RAC 10-480 NA compressed-air refrigeration dryer, the certified skilled personnel shall read up on the device by carefully studying the operating instructions.
Maintenance, troubleshooting, spare parts and dismantling DAILY: • Check whether the dew point indicated on the electronics is correct. • Ensure that the condensate drain system functions properly. • Make sure that the condenser is clean. EVERY 200 HOURS OR MONTHLY •...
Page 29
The dryer does not discharge the condensate – see the corresponding point. The hot-gas bypass valve needs to be re-adjusted – contact a BEKO service technician to have the nominal setting re-established. There is a leak in the refrigeration cycle – contact a BEKO service technician.
Page 30
6. The hot-gas bypass valve needs to be re-adjusted – contact a specialist for refrigerating plants to have the nominal calibration re-established. 7. There is a leak in the refrigeration cycle – please contact a BEKO service technician. Reset the temperature switch by manually pushing the button on the temperature switch –...
Maintenance, troubleshooting, spare parts and dismantling 12.3 Recommended spare parts NOTE: To order the recommended spare parts or other elements, the data on the name plate must be indicated. DRYPOINT® RAC 10-480 NA...
Page 32
Maintenance, troubleshooting, spare parts and dismantling DRYPOINT® RAC 10-480 NA...
When delivered, the dryer is ready to operate and filled with a refrigerant of the R134a or R407C type. Should you detect a refrigerant leak, please contact a BEKO service technician. Prior to any intervention, the room needs to be ventilated.