Connecting Ac Input Power; Figure 4-5 Ac Power Input Labeling - HP Integrity rx8620 User's & Service Manual

Hide thumbs Also See for Integrity rx8620:
Table of Contents
Cabling and Power Up

Connecting AC Input Power

Connecting AC Input Power
The server can receive AC input from two different AC power sources. If two separate power sources are
available, each source can be plugged into the server, increasing system reliability if one power source fails.
The main power source is defined to be A0 and A1. The redundant power source is defined to be B0 and B1.
See Figure 4-5 for the AC power input label scheme.
IMPORTANT When running the server with a single power source, you must use A0 and A1. Selecting
redundant power requires all four power cords connected to A0-A1-B0-B1.
Figure 4-5
AC Power Input Labeling
The power distribution for the Bulk Power Supplies is as follows:
A0 input provides power to BPS 0, BPS 1, and BPS 2
A1 input provides power to BPS 3, BPS 4, and BPS 5
B0 input provides power to BPS 0, BPS 1, and BPS 2
B1 input provides power to BPS 3, BPS 4, and BPS 5
78
B1 A1 B0 A0
Chapter 4