Table of Contents
4.
Select the setting number by pressing the SET TEMP.
The setting number indicator flashes during setting number selection.
5.
Confirm the setting by pressing the TIMER SET button.
The data will be transferred to the indoor unit.
● Data is not set up on the indoor unit
correctly (-- is displayed.)
● Set up the data again according to the
procedure in step 3, 4 above.
Function details: Refer to
6.
Exit the function setting mode by pressing the 3 buttons of SET TEMP.
FAN at the same time for 5 seconds or longer.
After exiting the function setting mode, the display returns to the normal mode.
If no button is pressed within 60 seconds after buttons mentioned above are pressed, it will au-
tomatically exit the function setting mode.
If you exit the function setting mode unintentionally during setting, enter the mode again ac-
cording to the procedure in step 2.
 Setting up each indoor unit
Repeat the procedures from step 1 to 6, and set up the indoor units requiring function setting.
1-4. Indoor unit (setting by simple remote controller)
Example) Function number : 30, Setting number : 01
Not good
Chapter 1-5. "Function details"
- (05-33) -
or SET TEMP.
Setting number
Good
Data is correctly set up on
the indoor unit.
on page 05-38.
, SET TEMP.
Normal mode display
button.
, and
1. Function settings (for indoor unit)