GE GXWH40L Installation Instructions Manual

GE GXWH40L Installation Instructions Manual

Heavy-duty water filtration unit
Hide thumbs Also See for GXWH40L:
Available languages

Available languages

Heavy-Duty Water Filtration Unit—GXWH40L (filters not included)
Check with your state and local public works department for
plumbing and sanitation codes. You must follow these guidelines
as you install the Heavy-Duty Water Filtration Housing. Using a
qualified installer is recommended.
Be sure the water supply conforms with the Performance Data .
If the water supply conditions are unknown, contact your
municipal water company.
This Heavy-Duty Water Filtration Housing must be properly installed and located in accordance with the Installation
Instructions before it is used.
Check with your local public works department for plumbing codes.
You must follow their guides as you install the Heavy-Duty Water
Filtration Housing.
Use the Heavy-Duty Water Filtration Housing on a potable, safe-to-
drink, home COLD water supply only. The filter cartridge will not
purify water or make unsafe water safe to drink. DO NOT use on
HOT water (100
°
F max).
Protect the Heavy-Duty Water Filtration Housing and piping from
freezing. Water freezing in the housing will damage it.
Your Heavy-Duty Water Filtration Housing will withstand up to 100
psi water pressure. If your house water supply pressure is higher
than 100 psi during the day (it may reach higher levels at night),
install a pressure-reducing valve before the housing is installed.

REQUIRED TOOLS AND ACCESSORIES

FOR INSTALLATION
■ 2 Adjustable wrenches
■ Pipe cutter
■ Ruler or tape measure
■ Cordless drill
■ File
■ Emery paper
■ Screwdriver
■ Additional installation parts may be required:
• 2 fittings to connect household plumbing to 1" female NPTF
threads on filter housing
• UL-approved grounding clamps and 6-gauge copper
grounding wire
• Teflon tape
INSTALLATION INSTRUCTIONS

SAFETY PRECAUTIONS

PROPER INSTALLATION

184D1061P003
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
GE
WARNING:
microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
It is highly recommended that a water shut-off valve be placed
directly upstream of your household filter.
Do not install on HOT WATER . The temperature of the water
supply to the Heavy-Duty Water Filtration Housing must be
between the minimum of 40°F and the maximum of 100°F.
See the Performance Data section.
Do not install the Heavy-Duty Water Filtration Housing using
copper solder fittings. The heat from the soldering process
will damage the unit.
WARNING:
material after installation. Small parts remaining after installation
could be a choke hazard.
Do not install filter in an outside location or anywhere it will be
exposed to sunlight.
Optional accessories are available (Visa, MasterCard or Discover cards
accepted) by visiting our Website at GEAppliances.com or from Parts and
Accessories, call 800.626.2002 (U.S.) or 800.663.6060 (Canada).

CONTENTS INCLUDED WITH PRODUCT

■ Filter housing and head
■ Product literature
■ Canister wrench
■ Timer and batteries
■ Mounting bracket
■ 4 Hex-head screws and 4 Hex washer-head screws
GXWH40L is Tested and Certified by NSF International
against NSF/ANSI Standard 42 with cartridge FXHTC
for the reduction of Chlorine, Taste and Odor.
49-50220-3
(04-09 JR)
GEAppliances.com
1
Do not use with water that is
Discard all unused parts and packaging
Table of Contents
loading

Summary of Contents for GE GXWH40L

  • Page 1: Safety Precautions

    Heavy-Duty Water Filtration Unit—GXWH40L (filters not included) ■ Check with your state and local public works department for plumbing and sanitation codes. You must follow these guidelines as you install the Heavy-Duty Water Filtration Housing. Using a qualified installer is recommended. ■...
  • Page 2: Specifications

    Inspect the filter canister O-ring. Make sure it is lightly lubricated with clean food-grade silicone grease (silicone grease is available through GE Parts and Service: 1.800.626.2002, part number WS60S10005). Be sure the O-ring is seated in the groove. It is recommended that you replace the O-ring if it is damaged.
  • Page 3 Select Location Select a location for the filter that is: ■ protected from freezing. Cut Water Line WARNING: A copper or galvanized cold water pipe may be used to ground electrical outlets in the home. Failure to maintain this ground path may result in an electric shock hazard. If the cold water pipe is used to ground electrical outlets, please refer to the Installing the Ground Wire section before cutting the pipe.
  • Page 4: Parts List

    Timer Installation and Reset Instructions Blue reset button Timer battery installation and change Insert coin or screwdriver in the slot between timer Timer cap cap and base. Gently pry them open and separate time base from cap. Install or change 2 new AAA 1.5-volt 2 AAA batteries batteries.
  • Page 5 Unité de filtration d’eau pour service rigoureux—GXWH40L (filtres non inclus) ■ Consulter le service local des travaux publics au sujet des codes de plomberie et de raccordement aux égouts. L’installation du logement de filtration d’eau pour service rigoureux doit être conforme aux prescriptions du code de plomberie local.
  • Page 6 (vous trouverez la graisse de silicone au service de pièces et d’entretien GE, en téléphonant au 1.800.626.2002, numéro de pièce WS60S10005). Assurez-vous que le joint torique repose bien dans le sillon. Remplacer le joint torique s’il est endommagé.
  • Page 7 à la terre des prises électriques de la maison. Cette mise à la masse vous protège contre les chocs électriques et cette liaison à la terre peut voir été neutralisée par le logement du filtre d’eau. Pour rétablir la connexion, montez un fil en cuivre de 18 po et de calibre 6 le long du...
  • Page 8 Installation de la minuterie et instructions de réglage Installation et remplacement de la pile de la minuterie Bouton bleu de remise à zéro Insérez une pièce ou un tournevis entre le capuchon de Capuchon de minuterie et sa base. Ouvrez doucement en faisant levier et la minuterie séparez la base de la minuterie de son capuchon.
  • Page 9 INSTRUCCIONES DE INSTALACION Unidad de filtración de agua extrafuerte—GXWH40L (filtros no incluidos) ■ Consulte con su departamento de obras públicas local y estatal para los códigos de plomería y sanidad. Usted debe seguir estas reglas a medida que instale el alojamiento de filtración de agua extrafuerte. El uso de un instalador calificado es recomendado.
  • Page 10 (la grasa de silicona está disponible a través del departamento de Partes y Servicio de GE llamando al 1.800.626.2002, número de parte WS60S10005). Cerciórese de que el aro tórico es asentado en la ranura.
  • Page 11 INSTRUCCIONES DE INSTALACION PASO A PASO (cont.) Seleccione la ubicación Seleccione una ubicación para el filtro que esté: ■ protegida de la congelación. ■ que no esté expuesta a la luz directa del sol. Corte de la línea de agua ADVERTENCIA: Se pueden usar tubos para agua fría en cobre o galvanizados para conectar a tierra las salidas eléctricas de la casa.
  • Page 12 Instalacion del cronometro e instrucciones de reinicialización Instalación y cambio de las baterías del cronómetro Botón de reajuste azul Inserte una moneda o un destornillador en la ranura entre Tapa del cronómetro la tapa y la base del sincronizador. Con gentileza haga palanca entre ellos y separe la base de tiempo de la tapa.

Table of Contents