  • Page 1 AquaMax Eco Premium 4000, 6000, 8000, 10000, 12000, 16000, 20000...
  • Page 2 WARNING WARNING Disconnect all electrical devices in the water from the power  supply before reaching into the water. Otherwise there is a risk of severe injuries or death by electrocution. This unit can be used by children aged 8 and above and by ...
  • Page 3: Safety Information

    Safety information Electrical connection • Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation. – The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces.
  • Page 4: Intended Use

    • Only carry out work on the unit that is described in this manual. • Only use original spare parts and accessories. • Should problems occur, please contact the authorised customer service or OASE. Intended use Only use the product described in this manual as follows: •...
  • Page 5: Product Description Overview

    Product Description Overview AMX0149 Inlet 1 (suction side) • Filter housing Inlet 2 (suction side) Connection of a satellite filter or skimmer. •...
  • Page 6: Symbols On The Unit

    • The flow rate at inlet 2 and with it the flow ratio of inlet 1 to inlet 2 is adjustable. To do so, re- lease the locking mechanism and push the connection to one of the following positions: − Position 0: Inlet 2 is closed, water flow only via inlet 1. −...
  • Page 7: Installation Variants

    Installation variants AMX0138 • Variant (a): Water flow only via the filter housing (inlet 1). – Set inlet 2 to position "0". – Close inlet 2 using the cover cap. • Variant (b): Water flow via the filter housing (inlet 1) and additionally via a satellite filter or a skimmer on inlet 2.
  • Page 8: Seasonal Flow Control (Sfc)

    SFC, the pump permanently operates at maximum throughput. The seasonal flow control does not function when the pump is installed on land (dry installation). If a skimmer, satellite filter or Oase InScenio control unit is used, we recommend deactivating the SFC depending on the unit.
  • Page 9: Installation And Connection

    Installation and connection The pump can be installed submerged (in water) or dry (outside the water). The use of the pump is only permitted with observance of the specified water quality. (→ Permissible water quality) WARNING Severe injuries or death due to operation of this unit in a swimming pond. Defective electrical components will electrify the water with dangerous electrical voltage.
  • Page 10: Submerged Installation Of The Pump

     Do not reach into the opening of the intake socket or pressure socket while the power plug is plugged in.  If the sockets are freely accessible during operation, e.g. if no hoses are connected, use a hand guard to secure the sockets. The hand guard is available as an accessory. NOTE If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear and will require earlier replacement.
  • Page 11 AMX0150 Do not plug the power plug into the socket yet! Installation...
  • Page 12 AMX0152 • Place the pump horizontally on a stable, mud-free surface. • Ensure secure and stable positioning of the pump. • Only operate the pump when it is fully submerged.  The pull rope allows you to simply pull the pump from the water. −...
  • Page 13 AMX0144...
  • Page 14: Installation

    Connecting AMX0151 Do not plug the power plug into the socket yet! Installation AMX0153 • Place the pump horizontally on a stable, mud-free surface. • Ensure secure and stable positioning of the pump.
  • Page 15: Switching On/Off

    Commissioning/start-up NOTE Prevent the pump from running dry. Otherwise the pump will be destroyed.  Only operate the pump when it is submerged or flooded. Switching ON/OFF • Switching on: Plug the power plug into the outlet. – The unit switches on immediately.
  • Page 16: Maintenance And Cleaning

    • When cleaning the pump, pay particular attention to the impeller unit and the pump housing. • Recommended cleaning agent for removing stubborn limescale deposits: – Pump cleaning agent PumpClean from OASE. – Vinegar- and chlorine-free household cleaning agent. • After cleaning, thoroughly rinse all parts in clean water.
  • Page 17 AMX0145 • Reassemble the unit in reverse order. • During reassembly check that – the clamp fastening the pump in the holder is securely engaged. – the connection cable is guided out through the groove in the housing and that it is not kinked or pinched significantly.
  • Page 18 AMX0146 Cleaning/replacing the impeller unit • Dismantle the pump as shown in the figure. • Use a brush under clear water to clean the components. • Check all components for damage. Replace damaged or worn components.  • Assemble the pump in reverse order. When the impeller is pulled out, the radial bearing in the motor housing may come loose.
  • Page 19 AMX0154 Storage/winter protection The unit is frost resistant to minus 20 °C. Should you store the unit outside of the pond, clean it thoroughly with a soft brush and water, check it for damage, then store immersed in water or filled with water. Do not immerse the power plug in water!
  • Page 20 Malfunction remedy Malfunction Cause Remedy Pump does not start No mains voltage Check the mains voltage. Supply lines kinked Route the supply lines without kinks Supply lines blocked. Check/clean the supply lines Impeller unit is blocked Remove blockage, check impeller unit for ease of movement Pump does not transport Filter housing clogged...
  • Page 21: Technical Data

    Technical data Unit data AquaMax Eco Premium 4000 6000 8000 10000 Connection voltage V AC 220 … 240 Mains frequency 50/60 50/60 50/60 50/60 Max. power consumption Max. pump capacity 4000 6000 8000 10000 Max. pump head Protection type IP68 IP68 IP68 IP68...
  • Page 22 (dry installation) During operation °C +4 ... +40 +4 ... +40 +4 ... +40 +4 ... +40 forced cooling Dimensions Length Width Height Connection cable length Weight AquaMax Eco Premium 12000 16000 20000 Connection voltage V AC 220 … 240 220 …...
  • Page 23: Wear Parts

    Permissible water quality Fresh water, pond water pH value 6.8 … 8.5 Hardness °dH 8 … 15 Free chlorine mg/l <0.3 Chloride content mg/l <250 Salt content <0.4 Overall dry residue mg/l <50 Temperature °C +4 … +35 Wear parts •...