Cisco Nexus 9348D-GX2A Hardware Installation Manual
Cisco Nexus 9348D-GX2A Hardware Installation Manual

Cisco Nexus 9348D-GX2A Hardware Installation Manual

Aci-mode switch

Quick Links

Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation
Guide
First Published: 2022-07-04
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Table of Contents
loading

Summary of Contents for Cisco Nexus 9348D-GX2A

  • Page 1 Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide First Published: 2022-07-04 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 © 2022 Cisco Systems, Inc. All rights reserved.
  • Page 3: Table Of Contents

    Unpacking and Inspecting a New Switch Planning How to Position the Chassis in the Rack Installing the Chassis in a Four-Post Rack Installing the Switch using the NXK-ACC-KIT2-2RU Rack-Mount Kit Grounding the Chassis Starting the Switch Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 4 A P P E N D I X B System Specifications Environmental Specifications Switch Dimensions Switch and Module Weights and Quantities Transceiver and Cable Specifications Switch Power Input Requirements Power Specifications 3200-W AC/HVDC Power Supply Specifications Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 5 A P P E N D I X C LEDs Switch Chassis LEDs Fan Module LEDs Power Supply LEDs A P P E N D I X D Additional Kits Rack Mount Kit NXK-ACC-KIT2-2RU Accessory Kit NXA-ACC-QDD-DC Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 7: Overview

    Overview • Overview, on page 1 Overview The Cisco Nexus 9348D-GX2A switch (N9K-C9348D-GX2A) is a 2-rack unit (RU), fixed-port switch designed for spine-leaf-APIC deployment in data centers. This switch includes the following ports: • 400-Gigabit QSFP-DD ports (48) • 10-Gigabit SFP+ ports (2) •...
  • Page 8 Both power supplies are the same type. Do not mix AC, and DC, power supplies. Note All fan modules and power supplies must use the same airflow direction. The following figure shows the switch features on the port side of the chassis. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 9 Power supply modules (1 numbered from 1 (left) to or 2) (AC power supplies 4 (right) shown) with slots numbered 1 (top) and 2 (bottom) The following figure shows the side of the chassis. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 10 If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 11: Preparing The Site

    Altitude Requirements Altitude rating is based on power supply installed; see critical components list in the system CB report for altitude rating. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 12: Dust And Particulate Requirements

    The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. If you exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 13: Shock And Vibration Requirements

    Planning for Power Requirements The switch includes two power supplies (1-to-1 redundancy with current sharing) in one of the following combinations: • Two 3200-W AC/HVDC power supplies Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 14 IEC 60950 based safety standards. Note We recommend 8-AWG wire for DC installations in the U.S. Note For the power cables to use with the power supplies, see Power Cable Specifications, on page Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 15: Airflow Requirements

    (for proper mounting of the bottom-support brackets or other mounting hardware). Also, you must have power receptacles that are located within reach of the power cords that are used with the switch. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 16: Clearance Requirements

    17.3 in (43.9 cm) 29.78 in (75.65 cm) Width of the front clearance area (equal to the width of the chassis with two rack-mount brackets that are attached to it). 19.0 in (43.3 cm) Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 17 Preparing the Site Clearance Requirements Note Both the front and rear of the chassis must be open to both aisles for airflow. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 18 Preparing the Site Clearance Requirements Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 19: Installing The Chassis

    You can install the switch using the following rack-mount options: • Rack-mount kit (NXK-ACC-KIT2-2RU) which you can order from Cisco. For four post racks. • Rack-mount kit (N9K-C9300-RMK) which you can order from Cisco.
  • Page 20: Unpacking And Inspecting A New Switch

    The shipment should include the following: • Switch chassis, which includes the following installed components: • Two power supplies (any combination of the following with the airflow direction being the same as for the fan modules): Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 21: Planning How To Position The Chassis In The Rack

    Installing the Chassis in a Four-Post Rack Before you install the chassis, be sure that the rack is fully secured to the data center floor. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 22: Installing The Switch Using The Nxk-Acc-Kit2-2Ru Rack-Mount Kit

    Install the two inner rails to the sides of the chassis using flat-head screws, as shown in the following illustration: Step 2 Install the two outer rails to the front posts of the rack by aligning the rails to the post holes, as shown in the following illustration: Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 23 Installing the Switch using the NXK-ACC-KIT2-2RU Rack-Mount Kit Step 3 Fasten the two outer rails to the front posts of the rack by pushing the latch into place, as shown in the following illustration: Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 24 Installing the Switch using the NXK-ACC-KIT2-2RU Rack-Mount Kit Step 4 Install the two outer rails to the back posts of the rack by extending them into place, as shown in the following illustration: Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 25 Installing the Switch using the NXK-ACC-KIT2-2RU Rack-Mount Kit Step 5 Fasten the two outer rails to the back posts of the rack by pushing the latch into place, as shown in the following illustration: Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 26 Then secure the retainer screws on the inner rails into the rack, as shown in the following illustration: Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 27 Then slide the retainer screws out to align with the rack and then secure the thumb-screws on the inner rails into the rack, as shown in the following illustration: Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 28: Grounding The Chassis

    Any paint or other non-conductive coatings shall be removed on the surfaces between the mounting hardware and the enclosure or rack. The surfaces shall be cleaned and an antioxidant applied before installation. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 29 Grounding cable, with 0.75 in. (19 mm) of insulation that is stripped from one end, which is inserted into the grounding lug and crimped in place Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 30: Starting The Switch

    Make sure that the connector clicks when fully pushed into the receptacle. b) Connect the other end of the power cable to a power source. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 31 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.
  • Page 32 Installing the Chassis Starting the Switch Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 33: Aci Fabric Topology

    As shown in the following figure, each APIC is connected to one or two leaf switches and each leaf switch should be connected to every spine switch in the same fabric. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 34: Preparing To Connect To Other Devices

    Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 35: Connecting Leaf Switches To Apics

    Connecting Leaf Switches to APICs You must downlink one or two (recommended for redundancy) Cisco Nexus 9300 platform ACI-mode leaf switches to each Application Policy Infrastructure Controller (APIC) in your ACI fabric. The type of virtual interface card (VIC) installed on the APIC determines the types of interface cables that you can use to connect the leaf switches to the APICs.
  • Page 36 Connect the other end of the interface cable to a downlink port on a leaf switch. • For a Cisco 10GBASE-LR or -SR transceiver and cable, insert the transceiver into a downlink optical port on a leaf switch before connecting the cable to the transceiver.
  • Page 37: Connecting Leaf Switches To Spine Switches

    You cannot include NX-OS line cards in the same chassis when running in ACI mode. Note Multiple uplinks from a leaf switch to a spine switch is supported. A symmetrical topology is recommended so that all devices have equal access to resources. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 38: Installing A Gigabit Ethernet Module (Gem)

    Migration of Nodes From a First Generation Switch to a Second Generation Switch You have first generation Cisco Nexus 9000 series switches that may or may not be comprising a virtual port channel (vPC). You are migrating to second generation Cisco Nexus 9000 series switches using the same cables.
  • Page 39 Before you begin • Move any Cisco Application Policy Infrastructure Controllers (APICs) that are connected to the first generation switches that you are migrating to any other switches in the fabric and wait for the Cisco APIC cluster to become "Fully Fit."...
  • Page 40: Setting Up An Optional Console Interface

    Register the new second generation switch with the Cisco APIC. Register the new node with the same node name and node ID. This switch becomes part of the fabric. The Cisco APIC pushes the policies to the new switch and keeps down the vPC legs because there is a mismatch of the generation of switches.
  • Page 41: Setting Up An Optional Management Connection

    DB-9 connector on the other end of the cable to the serial port on the console device. What to do next You can now perform the initial configuration for the switch (see the Cisco ACI Getting Started Guide). Setting Up an Optional Management Connection You can optionally set up an out-of-band management connection for monitoring and troubleshooting purposes.
  • Page 42 Use the narrow end of the optics extraction tool to carefully remove the transceiver module (see the following image). Step 4 Place the transceiver module in an antistatic bag or other protective environment. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 43: Maintaining Transceivers And Optical Cables

    • Inspect routinely for dust and damage. If you suspect damage, clean and then inspect fiber ends under a microscope to determine if damage has occurred. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 44 Connecting the Switch to the ACI Fabric Maintaining Transceivers and Optical Cables Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 45 Hold the module by its handle and do not touch the electrical connectors on its backside. Also, to protect the electrical connectors, avoid letting them come in contact with anything other than the electrical connectors inside the chassis. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 46 If the STS LED does not turn on, slide the module out of the chassis, and visually check the electrical connectors on the back side of the chassis for damage. If damaged, contact Cisco Technical Assistance for help. If undamaged, repeat the previous step to reinstall the module.
  • Page 47 Attach the power cable to the electrical outlet on the front of the power supply. Step 4 Make sure that the other end of the power cable is attached to the appropriate power source for the power supply. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 48 Depending on the outlet receptacle on your power distribution unit, you might need the optional jumper cable Note to connect the switch to your outlet receptacle. Step 5 Verify that the power supply is operational by making sure that the power supply LED is green. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 49 • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 50 • The roof should be perforated with at least a 20 percent open area. • The cabinet floor should be open or perforated to enhance cooling. The Cisco R Series rack conforms to these requirements. Cable Management Guidelines To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack.
  • Page 51: Environmental Specifications

    Altitude rating is based on power supply installed; see critical components list in the system CB report for altitude rating. Switch Dimensions Switch Width Depth Height Cisco Nexus 17.41 inches (44.23 cm) 29.82 in (75.76 cm) 3.45 inches (8.76 cm) (2 9348D-GX2A Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 52: Switch And Module Weights And Quantities

    Consumption (AC or DC) Consumption (AC or DC) Requirement Cisco Nexus 1380 W 3124 W 10,659.531 BTUs per 9348D-GX2A hour Power Specifications Power specifications include the specifications for each type of power supply module. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 53: Power Cable Specifications

    90% or greater (20 to 100% load) Redundancy Modes Combined, n+1, and n+n RoHS Compliance Hot Swappable Power Cable Specifications The following sections specify the power cables that you can order and use with this switch. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 54: Regulatory Standards Compliance Specifications

    Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC. Safety • CAN/CSA-C22.2 No. 60950-1 Second Edition • EN 60950-1 Second Edition • IEC 60950-1 Second Edition • IEC 623681 • AS/NZS 60950-1 • GB4943 Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 55 • CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 56 System Specifications System Specifications Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 57 Power supply is on and outputting power to the switch. Flashing Power supply is connected to an AC power source but not outputting power green to the switch. The power supply may not be properly installed in the chassis. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 58 Power supply is installed without a connection to a power source. (10 seconds) then amber Amber Power supply failure—possibly one of the following conditions: • Over voltage • Over current • Over temperature • Power supply fan failure Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 59 Not applicable Hazardous substances list for customers in China The following table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Illustration Description Quantity Console cable with DB-9F and RJ-45F connectors Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...
  • Page 60 The following table lists and illustrates the port dust cover (NXA-ACC-QDD-DC). Illustration Description Quantity The port dust cover is designed to protect the connectors in unused ports and help divert airflow for better thermal dispensation. Cisco Nexus 9348D-GX2A ACI-Mode Switch Hardware Installation Guide...