E
ON
Fig. 3 .: Diagrams of the operation principles of the TS-42-3 TWILIGHT SWITCH.
V. Repair and maintenance
All repairs of the TWILIGHT SWITCH TS-42-3 are performed by the manufacturer. The device does not
require any maintenance. When the sensor becomes contaminated, clean it with a clean, damp cloth. The
device does not require any additional maintenance.
The manufacturer guarantees the correct operation of the TS-42-3 TWILIGHT SWITCH. The warranty period
is 36 months from the date of sale. The warranty is extended by the time of repair. Warranty repairs are
performed by the manufacturer free of charge after the AUTOMAT is delivered to the manufacturer. Improper
use of the device or independent modifications to it will void the warranty.
................................................................................................................................................................................
www.mart-electronics.eu
The TS-42-3 TWILIGHT SWITCH meets the requirements of the European Union Directives:
- Directive LVD 2014/35/EU - Low Voltage Directive of 26 February 2014
- Directive EMC 2014/30/EU - Eletromagnetic Compatibility Directive of 26 February 2014
In order to protect the environment, do not throw away used electrical appliances
and electronics together with municipal waste. Used equipment should be delivered to
collection points for recycling free of charge. Any information on this can be obtained
at sellers, distributors, manufacturer or on the Internet. The product's packaging is made of
ecological materials. The PVC packaging tape will be used while stocks last.
t
OFF
VI. Warranty Card
Made in Europe
TWILIGHT SWITCH
TS-42-3 ECO
The TWILIGHT SWITCH TS-42-3 is designed to automatically switch the receiver on at the moment
of dusk and turn it off at dawn, or vice versa (NO, NC contacts). Two independent knobs for setting the switch-
on and switch-off thresholds allow for an optimal way to control the lighting. Independent adjustment of the
activation thresholds corrects the location of the sensor (north, south, east, west) and eliminates the hysteresis
that occurs in standard automatic units. Hysteresis causes switching off the lighting in the morning when the
lighting intensity is higher (2 ÷ 3 times) than the set lighting intensity level at which the lighting was turned on.
This causes an unfavourable extension of the lighting operation time in the morning, which results in an
increased consumption of electricity. On the other hand, too little hysteresis means that on cloudy days the
lamp may turn on and off with changing weather conditions, which is not advisable, and sometimes even
unacceptable for some lamps.
The light intensity measurement sensor has a spectrum similar to that of the human eye, and the adjustment
thresholds have logarithmic characteristics - also similar to the characteristics of the human eye.
Such an innovative design of the TS-42-3 TWILIGHT SWITCH makes the lighting control optimal, economic
and ecological.
The TS-42-3 TWILIGHT SWITCH includes:
>> TS-42 CONTROLLER - mounted in a distribution box on a 35 mm rail (one 18 mm module)
>> OUTDOOR SENSOR (IP65) - surface-mounted box mounted to the wall with two screws with a PG9 gland
to insert the cable. Connection cable not longer than 100m.
II. Features of the TWILIGHT SWITCH TS-42-3 ECO
>> Independent regulation of activation and deactivation thresholds
>> precise logarithmic adjustment:
> activation - 1 ... 10 ... 100 lx
> shutdown - 1 ... 10 ... 100 lx
>> high switching power - 16A (4000 W) 250VAC, 16A (384 W) 24VDC
>> high inrush current - resistance to 100 A surge current
>> freedom of connections:
> executive relay contacts (one normally open contact - NO, one normally closed contact - NC) galvanically
separated, which allows connections in various configurations
>> traffic light (LED):
> Green LED - indication of 230V AC supply voltage on LN terminals
> LED red:
- pulsating signalling (without delay) - the set (set) actuation threshold is exceeded
- continuous light - the level of the measured illuminance is between the settings on
knobs
> Blue LED - changeover indication - switching on (contact 1-2), disconnection (contact 2-3)
>> 35mm rail mount - one 18mm module.
The TS-42-3 CONTROLLER uses a specialized OMRON G2RL-1-E-HR relay, designed to switch various
types of lighting lamps. The special design of the relay enables effective switching of lamps with an inrush
current up to 100 A.