Honeywell H450EN - Carbon Monoxide Alarm Manual

Honeywell H450EN - Carbon Monoxide Alarm Manual

Also See for H450EN:
Honeywell H450EN - Carbon Monoxide Alarm Manual

INTRODUCTION

This manual contains information on the installation and operation of the Carbon Monoxide alarm.

Introduction

The status light flashes green at approximately 1 minute intervals to indicate that the unit is operating correctly. This will change to a yellow flash synchronised with chirp if a fault arises. The red alarm light will flash continuously and the buzzer will sound if Carbon Monoxide is present.

The unit is suitable for use in areas where cooking and heating appliances burn fuels such as wood, charcoal, coal, coke, oil, petrol, gas, etc.

WHAT IS CARBON MONOXIDE

Carbon Monoxide (CO) is a highly poisonous gas which is released when fuels are burnt. It is invisible, has no smell and is therefore very difficult to detect with the human senses. The first warning symptoms that CO is present in the air are usually headaches and nausea. Under normal operating conditions, in a room where fuel-burning appliances are well maintained and correctly ventilated, the amount of Carbon Monoxide released into the room by the appliances is not dangerous. A dangerous quantity of Carbon Monoxide can occur if one or more of the following conditions exists:

IN WHICH ROOM TO PUT THE ALARM

Ideally, an alarm should be fitted in every room that contains a fuel-burning appliance. However, if there is more than one appliance and the number of units is limited, the following points should be taken into consideration when deciding on the best location:

INSTALLING THE ALARM

The unit can either be free-standing or wall mounted, using the fixings provided.

WALL MOUNTING INSTALLATION

Find a position to install the unit (see"where to put the alarm" and "where not to put the alarm").

Option 1 Special Mounting Pad with Fixing Pin (supplied)

Place the fixing pin through the mounting pad. Using a hammer, gently knock the fixing pin into the wall ensuring that the mounting pad is not hammered too firmly into the wall.

Option 2 Screw and wall plug (NOT supplied)

If the wall is too hard to use the fixing pin, use a No. 4 round head screw and RawplugTM.
Mounting with screw and wall plug

Once activated and tested (see "using the alarm"), the unit can be hung on the protruding fixing pin using one of the 'keyholes' indicated on the back of the unit by the lines shown.

USING THE ALARM

To activate the unit, pull out the activation strip at the side of the unit. The green and red lights will flash briefly and the buzzer will sound a short chirp.
Using the alarm

Press the test button and hold for up to 5 seconds and check that the red light flashes and the buzzer sounds.

The unit is now operating and is ready for use.

EFFECTS OF CARBON MONOXIDE POISONING

Carbon Monoxide binds to the haemoglobin in the blood and reduces the amount of oxygen being circulated in the body.

200ppm Slight headaches, tiredness, dizziness, nausea after 2-3 hours.
400ppm Frontal headache within 1-2 hours, life threatening after 3 hours.
800ppm Dizziness, nausea and convulsions within 45 minutes. Unconsciousness with 2 hours. Death within 2-3 hours.
1600ppm Headache, dizziness and nausea within 20 minutes. Death within 1 hour.
6400ppm Headache, dizziness and nausea within 1-2 minutes. Death within 10-15 minutes.

POSITIONING THE ALARM

  1. Units located in the same room as a fuel-burning appliance
  2. Units located in sleeping rooms and in rooms remote from a fuel burning appliance

WHERE NOT TO PUT THE ALARM

Do not place the unit in the following areas:

CAREFULLY READ AND UNDERSTAND THE CONTENTS OF THIS INSTRUCTION MANUAL BEFORE USING THE ALARM. RETAIN THE MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.
PAY PARTICULAR ATTENTION TO THE SAFETY WARNINGS. PASS THE MANUAL ONTO ANY SUBSEQUENT USERS OF THE ALARM.


THIS CARBON MONOXIDE ALARM MAY NOT PROTECT PEOPLE WHO ARE AT SPECIAL RISK FROM CARBON MONOXIDE EXPOSURE BY REASON OF AGE, PREGNANCY OR MEDICAL CONDITION. IF IN DOUBT, CONSULT YOUR MEDICAL PRACTITIONER.

This Carbon Monoxide Alarm is NOT:


This Carbon Monoxide alarm is designed for indoor use only. Do not expose to rain or moisture. Do not knock or drop the unit. Do not open or tamper with the unit as this could cause malfunction.

The alarm will not protect against the risk of Carbon Monoxide poisoning when the battery has drained.

This pack contains:
One unit
One fixing kit
One instruction manual

TESTING YOUR CARBON MONOXIDE ALARM

The unit should be tested once a month by pressing and holding the test button on the front of the unit for 5 seconds, this tests the electrochemical cell, electronics and audible alarm. If the unit is functioning correctly, the green light will stay illuminated, the red light will flash and the alarm will sound. In case of a fault the unit is giving visual and audible signals once per minute. These signals can be triggered any time by pressing the test button.

SPECIFICATION

Model: H450EN
Gas Detected: Carbon Monoxide
Detection Principle: Electro-chemical cell
Alarm Indication: Flashing red light and audible alarm
Alarm Levels: 50ppm Between 60 to 90 mins
100ppm Between 10 to 40 mins
300ppm Less than 3 mins
Operating Temperature: -10˚C to 40˚C
Humidity Range: 30 to 90% RH non-condensing
Warm-up time after initial switch on: Instantaneous
Normal Operating Life: Up to 7 years
Battery life when in alarm: At least 5 days
Dimensions: 110mm x 76mm x 34mm
Weight: Approximately 110g

CARE AND MAINTENANCE OF ALARM

The Carbon Monoxide alarm is pre-calibrated at the factory and requires no maintenance other than to clean the outside case occasionally with a clean tissue. Ensure that the holes on the front of the unit are not blocked with dust or dirt. DO NOT USE CLEANING AGENTS, BLEACH OR POLISH.

END OF UNIT LIFE

The unit will operate for up to 7 years under normal use. The unit must be replaced when a low battery warning (1 chirp per minute or a fault warning signal (2 chirps per minute and the status light flashing yellow) is given. It is recommended to replace the unit after the date marked on the front of the unit.

DISPOSAL

When the unit has come to the end of its life, dispose of it in accordance with local regulations.

BATTERY DIRECTIVE STATEMENT


For safety reasons the H450EN is a sealed unit and the battery is not replaceable. At the end of the unit's life, if you have any concerns over the safe disposal of the unit/battery, please contact your local recycling centre or the Honeywell helpline printed in this manual.

OPERATION OF THE ALARM

Status Light Red Alarm Light Buzzer
Normal Operation
When no Carbon Monoxide is present, the status light will flash green approximately once every minute.
During normal operation the unit carries out a self-check test every 5 minutes.

Green
1 green flash per minute
Alarm Condition
When the unit detects Carbon Monoxide, it will give the alarm signal continuously. The red alarm light will flash and the buzzer will sound approximately 5 chirps per second.
5 chirps per 1 second
When the unit has been in alarm for 30 minutes the full alarm signal will be given once every minute. 5 chirps per 1 second per minute
Alarm Signal
The Carbon Monoxide alarm can be distinguished from smoke detector alarms as it signals C.O. in morse code (approximately 5 chirps per second).
Hush Feature
If required, the audible alarm can be silenced for 5 minutes by pushing the button marked 'Test'. The red alarm light will continue to flash 5 times per second.
5 flashes per 1 second

If Carbon Monoxide is still present after the 5 minute hush period, the audible alarm will sound.

NOTE: The hush facility will not operate at levels above 350ppm Carbon Monoxide. At levels below 350ppm the hush facility will only operate once, ie the audible alarm can only be silenced for one 5 minute period.

5 chirps per 1 second
Return to Normal Operation
When the Carbon Monoxide gas disperses, the alarm signal will stop. The status light will flash green approximately once every minute again.

Green
1 green flash per minute
Fault Warning
If a fault is detected the buzzer will sound 2 short chirps every minute. The unit must then be replaced.

Yellow
2 chirps per minute and yellow flash

Battery Fault Warning/End of Battery Life
The buzzer will sound 1 short chirp every minute.

NOTE: With normal use the batteries will last for up to 7 years. However, battery life will be reduced if either a fault occurs with the battery or the unit remains in alarm for long periods of time. Should the Battery Fault Warning occur please contact your supplier.


Yellow
1 chirp per minute and yellow flash

WHAT TO DO WHEN THE ALARM SOUNDS

If the unit raises an alarm, proceed as follows:

GAS EMERGENCY SERVICE TELEPHONE NUMBER
0800 111 999

Contact Numbers for OTHER FUEL Appliances:
OIL USERS: Contact OFTEC on 0845 658 5080
SOLID FUEL USERS: Contact HETAS on 0800 600 000
(Please note these numbers are only available during normal office hours)

Gas appliances should be checked for safety annually by a Gas Safe registered engineer. To find a registered engineer in your area call Gas Safe Register on 0800 408 5500 or look on the website: www.gassaferegister.co.uk.

User Manual also available in Braille. A Carbon Monoxide safety information sheet is available in: Punjabi; Urdu; Bengali; Gujarati and Hindi. For copies please call Honeywell Analytics on: 01202 645577

DECLARATION OF CONFORMITY

This product complies with European Directives for Low voltage 2006/95/EC and Electromagnetic Compatibility 2004/108/EC. The manufacturers full Declaration of Conformity may be found at the following website address: www.honeywellanalytics.com

DISCLAIMER

This Carbon Monoxide alarm is designed to alert you to a potentially dangerous build-up of Carbon Monoxide gas. It is not designed to remedy a Carbon Monoxide problem nor to locate a specific source of Carbon Monoxide. Honeywell shall not be liable to pay for any Carbon Monoxide investigation or service call carried out or arranged in response to an alarm.

GUARANTEE

We guarantee your new Carbon Monoxide alarm for six years from the date of purchase or until the expiry date on the front of the unit, whichever occurs first - under normal use and service, to be free from defects in materials and workmanship.

If you have further problems, please contact Honeywell Analytics helpline direct on +44 (0) 1202 645577. If units need to be returned, send them in suitable packaging along with proof of purchase to

CO Returns, Honeywell Analytics, 4 Stinsford Road, Nuffield Industrial Estate, Poole, BH17 0RZ.

Register your detector at www.sfdetection.com

Find out more www.honeywellanalytics.com

Contact us:
UK customer service centre
Honeywell Analytics Ltd.
4 Stinsford Road
Nutfield Industrial Estate
Poole, Dorset BH17 0RZ
Tel: +44 (0)1202 645577
Fax: +44 (0)1202 665331
[email protected]

Europe, Middle East, Africa, India
Life Safety Distribution AG
Weiherallee 11a
CH-8610 Uster
Switzerland
Tel: +41(0)44 943 4300
Fax: +41 (0)44 943 4398
[email protected]

Americas
Honeywell Analytics, Inc
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
[email protected]

Asia Pacific
Honeywell Analytics Asia Pacific
#508, Kolon Science Valley (I)
187-10 Guro-Dong, Guro-Gu
Seoul, 152-050
Korea
Tel: +82 (0)2 2025 0307
Fax: +82 (0)2 2025 0329
[email protected]

Technical Services
EMEAI: [email protected]
US: [email protected]
AP: [email protected]

www.honeywell.com

Please Note:
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Need Assistance?

Do you have a question about the H450EN that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents