INSTALLATION INSTRUCTIONS
Attention Installing Personnel
As a professional installer, you have an obligation to know
the product better than the customer. This includes all
safety precautions and related items.
Prior to actual installation, thoroughly familiarize yourself
with this Instruction Manual. Pay special attention to all safety
warnings. Often during installation or repair, it is possible to
place yourself in a position which is more hazardous than
when the unit is in operation.
Remember, it is your responsibility to install the product
safely and to know it well enough to be able to instruct a
customer in its safe use.
Safety is a matter of common sense...a matter of thinking
before acting. Most dealers have a list of specific good
safety practices...follow them.
The precautions listed in this Installation Manual are intended
as supplemental to existing practices. However, if there is a
direct conflict between existing practices and the content of
this manual, the precautions listed here take precedence.
Only personnel that have been trained to install, adjust,
service or repair (hereinafter, "service") the equipment
specified in this manual should service the equipment.
The manufacturer will not be responsible for any injury
or property damage arising from improper service or
service procedures. If you service this unit, you assume
responsibility for any injury or property damage which may
result. In addition, in jurisdictions that require one or more
licenses to service the equipment specified in this manual,
only licensed personnel should servise the equipment.
Improper installation, adjustment, servicing or repair of
the equipment specified in this manual, or attempting to
install, adjust, service or repair the equipment specified in
this manual without proper training may result in product
damage, property damage, personal injury or death.
Do not allow children to play on or around unit to
prevent injury.
HIGH VOLTAGE!
Disconnect all power befpore servicing or installing
this unit. Multiple power sources may be present.
Failure to do so may cause property damage, personal
injury or death.
Our continuing commitment to quality products may mean a change in specifications without notice.
IOD-7101
05 / 2019
WARNING
WARNING
WARNING
© 2019
5151 San Felipe St., Suite 500, Houston, TX 77056
Accessory Kit Numbers
KPS00301
KPS00302
KPS00303
Applicable Outdoor Unit Models
RZQ18TAVJU
RZQ24TAVJU
RZQ30TAVJU
RZQ36TAVJU
RZQ42TAVJU
RZQ48TAVJU
Safety Considerations .......................................................2
Before Installation ..............................................................2
www.daikincomfort.com
INSTALLATION INSTRUCTIONS
KPS00401
KPS00344
KPS00402
KPS00403
RZR18TAVJU
RXTQ36TAVJU
RZR24TAVJU
RXTQ48TAVJU
RZR30TAVJU
RXTQ60TAVJU
RZR36TAVJU
RXSQ24TAVJU
RZR42TAVJU
RXSQ36TAVJU
RZR48TAVJU
RXSQ48TAVJU
RXSQ60TAVJU
INDEX
loading

Summary of Contents for Daikin RZQ18TAVJU

  • Page 1: Table Of Contents

    Instruction Manual. Pay special attention to all safety Applicable Outdoor Unit Models warnings. Often during installation or repair, it is possible to place yourself in a position which is more hazardous than RZQ18TAVJU RZR18TAVJU RXTQ36TAVJU when the unit is in operation.
  • Page 2 SAFETY CONSIDERATIONS Read these Safety Considerations carefully before installing WARNING the snow hoods. After completing the installation, make sure Use only specified accessories and parts for installation that the unit operates properly during the startup operation. work. Failure to use specified parts could result in water leakage.
  • Page 3 32.88" 4.09" 2.00" 17.1" Components Make sure that the accessories shown below are all present. REAR 1.59" NAME SNOW HOOD PANELS SET SCREW MANUALS, ETC. 12.63" QUANTITY SEE BELOW .88" QUANTITY 1 pc. 3.60" 2.00" ADDED ROW Single/Double Fan - Punch # Snow Visor (Assembled)
  • Page 4 Components (cont.) NAME SNOW HOOD PANELS SET SCREW MANUALS, ETC. QUANTITY SEE BELOW QUANTITY 1 pc. Double Fan – Punch # FRONT (Assembled) KPS00401 Panel Quantity: Sheet metal 8pcs Punch # Double Fan – REAR INSTALLATION (Assembled) MANUAL KPS00403 Panel Quantity: Sheet metal 4pcs Punch # Double Fan –...
  • Page 5: Special Considerations Before Snow Hood Installation

    SPECIAL CONSIDERATIONS BEFORE SNOW HOOD INSTALLATION 1. These snow hoods extend approximately 22” beyond the 2. It is recommended that the condensing units be mounted front, rear and sides of the condensing unit when installed. at least 12” higher than the average snowfall amount for Please keep this in mind when planning new installations or the location.
  • Page 6: Single/Double Fan Snow Visor Installation

    SINGLE/DOUBLE FAN SNOW VISOR INSTALLATION 1. Remove all existing screws from the top section of the condenser unit (save all). 2. Carefully place the snow visor assembly on top of the unit and secure using the saved existing screws...
  • Page 7: Single/Double Fan Front Snow Hood Installation

    SINGLE/DOUBLE FAN FRONT SNOW HOOD INSTALLATION (Image 1b) Front Snow Hood Assembly 4. Install SIDE2 to the condenser unit by placing it behind 1. Unscrew the four (4) screws that are holding the Plastic the fan guard metal on the top and bottom. Align the grill.
  • Page 8 7. Install TOP2 securing to the hood sides using eight (8) provided screws (Image 1f). (Image 1f) (Image 1d) 8. Install TOP1 with its lower flange sitting above TOP2 and 6. Reinstall the front plastic grill removed in step 1 (Image 1e). securing to the hood sides using two (2) provided screws (Image 1g).
  • Page 9 *Double Fan – Repeat above process for both fans* Start with BOTTOM fan FIRST* (Image 2a) (Image 1h) 9. Secure TOP1 & TOP2 together by using one (1) provided screw in the middle. (Image 1h) (Image 2a)
  • Page 10: Single/Double Fan Rear Snow Hood Installation

    SINGLE/DOUBLE FAN 2. Remove the four (4) existing screws from the left side of REAR SNOW HOOD INSTALLATION the condenser unit and save (Image 3b). Rear Snow Hood Assembly 1. Remove the plastic grill from the condenser unit (Image 3a). (Image 3b) 3.
  • Page 11 5. Attach TOP1 to SIDE1 and SIDE2 using six (6) provided CAUTION screws on the surface; two (2) provided screws on the When installing SIDE2 use care not to damage the bottom. Do not put screws in 2 upper holes (Image 3f). Condenser Sensor 4.
  • Page 12: Single/Double Fan Side Snow Hood Installation

    SINGLE/DOUBLE FAN SIDE SNOW HOOD INSTALLATION 2. Place SIDE1 on top of the top right screw (hanging from the screw (Image 4b)) (Image 4b) Side Snow Hood Assembly 1. Install two (2) provided screws into the top side holes (one 3.
  • Page 13 4. Insert four (4) provided screws into existing holes; two (2) on each side of the condenser unit. 5. Tighten screws on both sides. 6. Attach TOP1 to SIDE1 and SIDE2. • Secure TOP1 to SIDE1 and SIDE2 using six (6) provided (Image screws.
  • Page 14 THIS PAGE LEFT INTENTIONALLY BLANK...
  • Page 15 THIS PAGE LEFT INTENTIONALLY BLANK...
  • Page 16 CUSTOMER FEEDBACK Daikin is very interested in all product comments. Please fill out the feedback form on the following link: https://daikincomfort.com/contact-us You can also scan the QR code on the right to be directed to the feedback page. Our continuing commitment to quality products may mean a change in specifications without notice.