The StudSensor e50 features two scanning modes:

  • DEEPSCAN®: Locates the edges of wood and metal studs up to 38 mm deep

WireWarning® detection automatically detects and alerts the user to live AC wires in STUD SCAN and DEEPSCAN® modes. When AC voltage is detected, the AC WireWarning® icon will be displayed on screen.
Features

INSTALLING THE BATTERY

Push in the battery door tab at the bottom of the tool and open the door.

Insert a new 9 V battery, matching the positive (+) and negative (-) terminals to the icons printed on the back. Snap the battery into place and replace the door.
Installing the Battery

OPERATING TIPS

For optimum scanning results:

  • To avoid surprises, remember that studs or joists are normally spaced 41 or 61 cm apart and are 38 mm in width. Anything closer together or a different width may not be a stud, joist, or firebreak.

If you're receiving erratic scanning results, it may be a result of humidity, moisture within the wall cavity or drywall, or recently applied paint or wallpaper that hasn't fully dried. While the moisture may not always be visible, it will interfere with tool's sensors. Please allow a few days for the wall to dry out.


Do not rely exclusively on the detector to locate items behind the scanned surface. Use other information sources to help locate items before penetrating the surface. Such additional sources include construction plans, visible points of entry of pipes and wiring into walls, such as in a basement, and in standard 41 and 61 cm stud spacing practices.

Always turn off the power when working near electrical wires.

WORKING WITH DIFFERENT MATERIALS

StudSensor e50 is for use on dry interior walls only.

Note: Sensing depth and accuracy can vary due to moisture, content of materials, wall texture, and paint.

StudSensor e50 can scan effectively through most sheet materials, including:

  • Bare wood flooring (in DEEPSCAN® mode)

StudSensor e50 is not designed to scan materials such as:

SELECTING THE MODE

Move selector switch to the desired mode:

STUD SCAN for finding wood or metal studs or DEEPSCAN® for finding studs behind walls more than 19 mm thick.

Unit will remain off if Power button is not depressed.

FINDING A STUD

Always scan for studs with the scanner placed flat against the wall. Move the mode switch to STUD SCAN, place the tool flat against the wall, then press and hold the Power button. Wait for beep to confirm calibration has completed before moving scanner.

Continue to hold the Power button, then slowly slide unit horizontally across the wall, left or right. As you begin to approach a stud, the arrow segments will begin to turn on.
Finding a Stud - Turning on

When the full arrow is first displayed, the SpotLite® pointer shines, and a steady tone sounds, you have located the edge of the stud. Mark this spot.
Finding a Stud - Marking the edge

Without releasing Power button, continue scanning beyond marked spot until some segments of the arrow turn off. Slide unit in reverse direction to locate other edge of stud.
Finding a Stud - Locating other edge of stud

Mark this second spot. Middle of stud is centred between the two marks.
Finding a Stud - Marking the second edge

WIREWARNING DETECTION

WireWarning® detection works continuously in STUD SCAN and DEEPSCAN® modes. When live AC voltage is detected, the WireWarning® indicator will appear on the display. If scanning begins over a live AC wire, the WireWarning® indicator will flash continuously. Use extreme caution in these circumstances or whenever live AC is present.


Electrical field locators may not detect live AC wires if moisture is present in the wall, or if wires are more than 51 mm from the scanned surface, in plastic conduit or behind a plywood shear wall or metallic wall covering.

burn hazardburn hazard
DO NOT ASSUME THERE ARE NO LIVE ELECTRICAL WIRES IN THE WALL. DO NOT TAKE ACTIONS THAT COULD BE DANGEROUS IF THE WALL CONTAINS A LIVE ELECTRICAL WIRE. ALWAYS TURN OFF THE ELECTRICAL POWER, GAS, AND WATER SUPPLIES BEFORE PENETRATING A SURFACE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN ELECTRIC SHOCK, FIRE, AND/OR SERIOUS INJURY OR PROPERTY DAMAGE.
Wirewarning detection

HELPFUL HINTS

See also Operating Tips

Situation Probable Causes Solutions
All LCD icons flash and the unit beeps continuously.

Unable to detect studs in STUD SCAN mode.

Middle LCD segment doesn´t turn on or flash in STUD SCAN mode.

The TruCal® icon turns on but, when scanning, unit doesn´t do anything else.
  • If it is in the DEEPSCAN® mode (DEEPSCAN® is lit), you may have calibrated over a stud.
Working in DEEPSCAN® mode and can´t detect studs.
  • You may have calibrated over a stud. (The error condition is disabled in DEEPSCAN® mode because it is twice as sensitive as STUD SCAN.)
Detects other objects besides studs.
You suspect electrical wires, but do not detect any.
Always turn off power when cutting, nailing, or drilling near electrical wires.
Area of voltage detection appears much larger than actual wire
(AC only).
Always turn off power when cutting, nailing, or drilling near electrical wires.

DeepScan, SpotLite, StudSensor, TruCal, WireWarning, and Zircon are registered trademarks or trademarks of Zircon Corporation.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Need Assistance?

Do you have a question about the StudSensor e50 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents