Honeywell BW Solo - Portable Single Gas Detector Quick Reference Guide

Honeywell BW Solo - Portable Single Gas Detector Quick Reference Guide

Also See for BW Solo:
Honeywell BW Solo - Portable Single Gas Detector Quick Reference Guide

Overview

Overview - Front

  1. Display
  2. LED visible alarm ring
  3. Light sensor
  4. Control button
  5. Non-compliance
  6. Filter reference window
  7. Gas inlet
  8. Audible alarm beeper
  9. Sensor type

Overview - Back

  1. Clip
  2. IR communication port
  3. Battery compartment
  • For safety reasons, this equipment must be operated and serviced by qualified personnel only.
  • Read and understand the instruction manual completely before operating or servicing.
  • Substitution of components may impact safety.
  • Lithium battery: Only use approved battery: 2/3AA 3.6V 1.65Ah Lithium battery (P/N: 500-0160-000).

  • To reduce the risk of electric shock, turn the power off before opening this instrument or performing service.
  • Never operate the instrument when the instrument is open.
  • Service this product only in an area known to be non-hazardous.
  • Recycling: this instrument contains a lithium battery. Do not mix with the solid waste stream. Spent batteries should be disposed of by a qualified recycler or hazardous materials handler.
  • This device complies with Part 15 of the FCC Rules / Industry Canada licenseexempt RSS standard(s). Operation is subject to the following two conditions:

Common device's operations

Common device’s operations

Power On 5-second hold
Power Off 5-second hold
Enter Menus Double-click
Select Next Single-click
Initiate Selected Long Hold


Read the User Guide for complete information on the BW Solo operation.

Bump Test/Configuration

  1. Press twice repeteadily
    Bump Test/Configuration - Step 1
  2. Select Bump Test or Configuration, and then follow On-screen instructions until ''Apply Gas?" is displayed.
  3. Place the calibration cap over the Honeywell BW Solo, and then hook the cap's left clip to the corresponding groove of the detector.
    Bump Test/Configuration - Step 2
  4. Press down on the tab to snap the right clip into place.
  5. Attach hose and open the cylinder valve by turning the pressure regulator knob counterclockwise.
    Bump Test/Configuration - Step 3
  6. Remove the calibration cap by pulling on the tab.
    Bump Test/Configuration - Step 4

Contact Us

Europe, Middle East, Africa
Life Safety Distribution GmbH
Toll-Free 00800 333 222 44
Middle East +971 4 450 5800
Middle East +971 4 450 5852
(Portable Gas Detection)
[email protected]

Americas
Honeywell Analytics Distribution Inc.
Tel: +1 847 955 8200
Toll free: +1 800 538 0363 [email protected]

RAE Systems by Honeywell
Phone: 408.952.8200
Toll Free: 1.888.723.4800

Asia Pacific
Honeywell Analytics Asia Pacific
Tel: +82 (0) 2 6909 0300
India Tel: +91 124 4752700
[email protected]

Technical Services
EMEA: [email protected]
US: [email protected]
AP: [email protected]

www.honeywellanalytics.com www.raesystems.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Need Assistance?

Do you have a question about the BW Solo that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents