MULTI-REG CONTROL IP54
Page 1 of 24
Table of Contents
loading

Summary of Contents for S&P MULTI-REG CONTROL 2841 Series

  • Page 1 MULTI-REG CONTROL IP54 Page 1 of 24...
  • Page 2 Page 2 of 24...
  • Page 3: Table Of Contents

    ENGLISH INDEX RECOMMENDATIONS ..........................5 TRANSPORT AND HANDLING ......................5 GENERAL ..............................5 3.1. Speed Control Inputs ..........................5 3.2. Installer-defined Fixed Speed Control ....................... 5 3.3. Remote Switching ............................ 6 3.4. Fan-Fail Detection by Fault Sensing ......................6 3.5. Outputs ..............................
  • Page 4 Page 4 of 24...
  • Page 5: Recommendations

    1. RECOMMENDATIONS Thank you for placing your confidence in S&P by buying this product. It has been manufactured following current technical safety regulations and in compliance with EC standards. Please read this instruction booklet carefully before installing or starting up the product. It contains important information on personal and user safety measures to be followed while installing, using and carrying out maintenance work on the equipment.
  • Page 6: Remote Switching

    3.3. Remote Switching  The switching between the (up to) three speeds can be activated by either:  (Up to) Three Volt-free contacts, or  (Up to) Three 230V supply inputs  On/Off – Volt-Free Contact and/or 230V  External Fire Fan Shut-Off Switch – An external “Fire” switch (Volt-Free) can be connected, If the switch opens signifying that the fire alarm has been activated, then the MULTI-REG Controller will automatically stop the fan.
  • Page 7: Specification

    4.3. SPECIFICATION  The MULTI-REG control is designed for continuous operation with the maximum rated current load listed in table 1 at 40° C. ambient on single phase 230 Volts ~ 50Hz supply.  The normal equipment temperature range is -20°C to +40°C. ...
  • Page 8: Fan Wiring

    5. FAN WIRING This basic wiring must be followed for every installation!!! L – Live N – Neutral E – Earth Fault monitoring (Tacho) To monitor the status of fan change TACHO jumpers from ‘OFF’ to ‘ON’. If you are using ‘FAN 1 O/P’ change TACHO 1 to ‘ON’ If you are using ‘FAN 2 O/P’...
  • Page 9: Control Wiring

    6. CONTROL WIRING 6.1. REMOTE ENABLE VIA EXTERNAL VOLT-FREE CONTACT Fan speed set-point (Min Speed) The speed is defined by the ‘Min speed’ Potentiometer, by rotating the potentiometer dial it will change the set speed of the fan. Page 9 of 24...
  • Page 10: Remote Enable Via External Switched 230V Supply

    6.2. REMOTE ENABLE VIA EXTERNAL SWITCHED 230V SUPPLY Fan speed set-point (Min Speed) The speed is defined by the ‘Min speed’ Potentiometer, by rotating the potentiometer dial it will change the set speed of the fan. Page 10 of 24...
  • Page 11: Continuous Running With Two Optional Speeds Via External Volt-Free Contacts

    6.3. CONTINUOUS RUNNING WITH TWO OPTIONAL SPEEDS VIA EXTERNAL VOLT-FREE CONTACTS Trickle speed set-point (Min Speed) The speed is defined by the ‘Min speed’ Potentiometer, by rotating the potentiometer dial it will change the set speed of the fan. Optional second speed (Mid Speed) The speed is defined by the ‘Mid speed’...
  • Page 12: Continuous Running With Two Optional Speeds Via External Switched 230V Supply

    6.4. CONTINUOUS RUNNING WITH TWO OPTIONAL SPEEDS VIA EXTERNAL SWITCHED 230V SUPPLY Trickle speed set-point (Min Speed) The speed is defined by the ‘Min speed’ Potentiometer, by rotating the potentiometer dial it will change the set speed of the fan. Optional second speed (Mid Speed) The speed is defined by the ‘Mid speed’...
  • Page 13: Remote Enable And Speed Control Via External Reb-Ecowatt

    6.5. REMOTE ENABLE AND SPEED CONTROL VIA EXTERNAL REB-ECOWATT PRIOR TO ENERGISING THE MULTI-REG, THE INSTALLER MUST SET ALL THREE OF THE SPEED POTENTIOMETERS TO THEIR MINIMUM (FULLY ANTI-CLOCKWISE) POSITION. Fan speed The speed is defined by rotating the dial on the REB-ECOWATT. Page 13 of 24...
  • Page 14: Remote Enable And Speed Control Via External Reb-Cvf

    6.6. REMOTE ENABLE AND SPEED CONTROL VIA EXTERNAL REB-CVF PRIOR TO ENERGISING THE MULTI-REG, THE INSTALLER MUST SET ALL THREE OF THE SPEED POTENTIOMETERS TO THEIR MINIMUM (FULLY ANTI-CLOCKWISE) POSITION. Fan speed The speed is defined by rotating the dial on the REB-CVF. Page 14 of 24...
  • Page 15: Continuous Running With Two Optional Speeds Via External Switched 230V Supply

    6.7. CONTINUOUS RUNNING WITH TWO OPTIONAL SPEEDS VIA EXTERNAL SWITCHED 230V SUPPLY PRIOR TO ENERGISING THE MULTI-REG, THE INSTALLER MUST SET ALL THREE OF THE SPEED POTENTIOMETERS TO THEIR MINIMUM (FULLY ANTI-CLOCKWISE) POSITION. Fan speed (0-10V) The speed is defined by the highest voltage of the two 0 - 10V signals from the external devices; the minimum output is 3V.
  • Page 16: Remote Enable Via 7-Day Timer (1000001114)

    6.8. REMOTE ENABLE VIA 7-DAY TIMER (1000001114) Fan speed set-point (Min speed) The speed is defined by the ‘Min speed’ Potentiometer, by rotating the potentiometer dial it will change the set speed of the fan. Page 16 of 24...
  • Page 17: Run And Fault Relay

    6.9. RUN AND FAULT RELAY Run relay (Maximum current load 8A) Fan Running – Continuity between COM and NO Fan Stopped – Continuity between COM and NC Fault relay (Maximum current load 8A) Fan Running/Stopped – Continuity between COM and NC Fault with Fan –...
  • Page 18: Fault Inputs

    6.10. FAULT INPUTS External fault switch (SW1) When the fan is in normal running conditions the switch should be in the closed position. If additional switches are required then they can be connected in series. During start-up there is a 60 seconds delay to allow the airflow to increase.
  • Page 19: Damper

    6.11. DAMPER Damper actuator When the fan is running, the damper opens. When the fan is stopped (intentionally or in a fault condition) the damper’s spring return facility closes the damper. Page 19 of 24...
  • Page 20: Over-Run Timer

    6.12. OVER-RUN TIMER Operation: The over-run timer works when you alter the ‘Timer’ potentiometer, this will allow you to add an over-run of 0 to 15 minutes; the over-run function will operate for both remote enable and boost functions. If a 10 minute over-run is set then the remote enable will over-run for 10 minutes and the boost will over-run for 10 minutes.
  • Page 21: Fan Speed Offset

    6.13. FAN SPEED OFFSET Operation: The fan speed offset works when you alter the ‘Off-set Output 2’ potentiometer, this will allow you to alter the fan 2 output by +3V or -3V; this is limited by the minimum output 3V and maximum output 10V.
  • Page 22: Maintenance

    7. MAINTENANCE  Before handling the ventilator, make sure it is disconnected from the mains supply even if it has previously been switched off. Prevent the possibility of anyone else connecting it while it is being worked on.  The apparatus must be regularly inspected. These inspections should be carried out bearing in mind the ventilator’s working conditions, in order to avoid dirt or dust accumulating on the impeller, motor or back-draught shutter.
  • Page 23: Guarantee

    11. GUARANTEE S&P Limited Warranty 24 (TWENTY FOUR) MONTH PRODUCT WARRANTY S&P UK Ventilation Systems Limited warrants that the MULTI-REG Control will be free from defective materials and workmanship for the period of 24 (twenty four) months from the date of original purchase.