Defrost Inner Wall; Battery Maintenance - Haier DW-86L338 Service Manual

Ultra-low temperature refrigerator
Hide thumbs Also See for DW-86L338:
Table of Contents
 

4. Defrost inner wall

Generally, frost occurs on the upper part of refrigerator body and inner door. Frost may cause 
gap  between  refrigerator  body  and  door  sealing  strip,  which  may  cause  bad  refrigerating 
effect.  Defrost  on  inner  door  with  a  defrosting  shovel,  which  is  provided  together  with  the 
equipment. Empty refrigerator body, and then defrost according to the following method: 
Note: Don't defrost with the tools that have sharp edge and corner, for example, a knife or a screw 
driver. 
1. Take out objects in refrigerator and put them into another storage box, or a container with 
freezing liquid‐state carbon dioxide. 
2. If there is an aided cooling device, turn off the device. 
3. Turn off the power. 
4. Open outer door and inner door, let refrigerator outer door naturally open for a period of 
time to melt frost. 
5. Use a dry cloth to wipe off the water on refrigerator bottom.   
6. After finishing cleaning refrigerator body and inner door, restart the equipment. 
7. Put the objects back into already fully‐cooled refrigerator body. 
8. If there is an aided cooling device, turn on the device. 
 

5. Battery maintenance

When  low‐temperature  storage  box  is  continuously  working,  please  check  the  electricity 
quantity of battery. When you find the electricity quantity of battery is low, please ensure that 
battery  switch  is  ON,  at  this  time,  the  battery  is  recharged.  When  the  battery  has  been 
recharged continuously for a week, please test the electricity quantity of battery again; under 
normal  condition,  at  this  time,  the  electricity  quantity  of  battery  should  be  full.  If  the 
condition  of  insufficient  electricity  quantity  of  battery  still  appears,  please  replace  the 
rechargeable battery. 
Power‐off alarm battery is a consumable. The life service of battery is about 3 years. If battery 
is  used  more  than  3  years,  it  may  not  fail  to  act  at  the  time  of  alarming,  and  the  setting  of 
 
 