Summary of Contents for Dormakaba phi Olympian 100 Series

  • Page 1 Olympian 100, 200, 300 Series Exit Devices Strength by design. Simply PRECISION...
  • Page 2 TABLE OF CONTENTS Exit Devices & Trims Accessories Rim Devices ......................4, 5 Cylinders ........................13 Surface Vertical Rod Devices ................6, 7 Miscellaneous Components ................12 Mortise Devices .....................8, 9 Security Screws......................3 Sex Nuts & Bolts ......................3 Mullions Strikes ...........................10 Fire Labeled Removable Mullion ..............11 Key Removable Mullion ..................11 Additional Information Removable Mullion ....................11...
  • Page 3: General Information

    General Information Door Sizes Stock sizes for door widths and heights are listed below. If required, cut to size in the field. Door Widths Stock Sizes 2’-6” * 2’-1” to 2’-6” 3’-0” 2’-7” to 3’-0” 4’-0” 3’-1” to 4’-0” *Not available for Narrow Stile Devices. Vertical Rod Devices Device Door Heights...
  • Page 4 Rim Exit Devices S300 Standard S458 Optional S988 Optional Olympian 100 Series - Handed Handed – 100, FL100 Devices are Handed. Specify Hand as Olympian R100 Series - Reversible RHRB or LHRB. Standard packing RHRB. Olympian FL100 Fire Exit Series - Handed Reversible –...
  • Page 5 Trims 1700A 1700B 1700C 2000C 1. All Trims are furnished with wrought plates and extruded or cast solid grips. “A” Grip “B” Grip “C” Grip “C” Grip 2. Specify Grip Design (A,B,C) (“A” Grip furnished standard for 1700 Series Trim, “C” Grip furnished standard for 2000 Series Trim) V4908A 4900A...
  • Page 6 Surface Vertical Rod Exit Devices Olympian 200 Series - Non Handed Olympian FL200 Fire Exit Series - Non Handed Doors – For all types of single and double door Dogging – Hex Key dogging standard for Panic Hardware. NOT applications. Available for 1-3/4” to 2-1/4” thick, up to available on Fire Exit Hardware.
  • Page 7 Trims 1700A 1700B 1700C 2000C 1. All Trims are furnished with wrought plates and extruded or cast solid grips. “A” Grip “B” Grip “C” Grip “C” Grip 2. Specify Grip Design (A,B,C) (“A” Grip furnished standard for 1700 Series Trim, “C” Grip furnished standard for 2000 Series Trim) V4908A 4900A...
  • Page 8 Mortise Exit Devices S982 Olympian 300 Series - Handed Mortise Lock - Handed Olympian FL300 Fire Exit Series - Handed Fits doors machined per ANSI A115.1 for Federal Lock Type Doors – For all types of single and double door applications. Available for 1-3/4”...
  • Page 9 Trims 1700A 1700B 1700C 2000C 1. All Trims are furnished with wrought plates and extruded or cast solid grips. “A” Grip “B” Grip “C” Grip “C” Grip 2. Specify Grip Design (A,B,C) (“A” Grip furnished standard for 1700 Series Trim, “C” Grip furnished standard for 2000 Series Trim) 3.
  • Page 10 STRIKES Rim Exit Devices For Minimum Stile Widths see page 14. 1-1/8” 1-1/8” 1-1/8” 3/4” 3/4” 1/2” 1-3/4” 1/2” 2-7/8” 2-7/8” 2-7/8” 2” S300 Standard S301 Optional S458 Optional S988 Standard For Rim and Top Strike for SVR For Rim and Top Strike for SVR For Rim Devices.
  • Page 11 Mullions Mullion MC822 Key Removable Mullion Cap Spacer Mullion Cap MCS822 KMC822 (Rim Cylinder required) Stabilizer Interlock ST989 S1447 Removable Mullions The Mullion is used to adapt a double door opening to two single door openings with Rim Exit Devices. When the full width of an opening is required, the mullion may be removed.
  • Page 12 ACCESSORIES Back Plate Assemblies BP103 BP108 Back plate assembly for 100, R100, FL100 and FLR100 Devices Back plate assembly for 100, R100, FL100 and FLR100 Devices to convert to Night Latch (03) function. to convert to thumbpiece (05, 15) or knob/lever (08, 14) functions.
  • Page 13 Trim Dimensions 1700A 1700B 1700C 2000C 3/8” 15” 15” 15” 15” 2-1/2” 6” 6” 6” 6” 2-1/2” 2-3/4” 2-1/8” 2-3/4” 2-3/8” 2-3/4” 2-1/2” 1-3/4” 2-7/16” 4900B 4900C 4900D 4900K 4900A 4-7/8” 4-1/2” 4-7/8” 4-5/8” 2-1/16” 7/16” 4-1/8” 7/16” 7/16” 2-3/4” 2-3/4”...
  • Page 14 MINIMUM STILE WIDTH Single Doors – Rim Devices Stile Width Stile Width Stile Width 3-1/2” Min. 4-1/4” Min. 4-1/4” Min. 2-3/4” 2-3/4” Backset 1-15/16” Backset Backset 2-1/4” 2-1/16” Strike Strike Rim Device with S300 Rim Device with S988 Strike For 3-1/2” Mortise Device OR S301 Strike medium stile Aluminum doors and...
  • Page 15 Fire Label Rating UL Fire Door Rating Type and Door Exit Device Application Opening Series 1-1/2 1-1/2 min. Hour Hour Hour Hour Hour Door Single Door Rim Device 4’-0”W x 10’-0”H FL100, FLR100 • • • • • • Mortise Device 4’-0”W x 10’-0”H FL300 •...
  • Page 16 6161 East 75th Street Indianapolis, IN 46250 USA Phone 855-365-2407 precisionhardware.com PHI007 • Rev 06/27/2018 dormakaba.com © 2018 dormakaba Holding. All rights reserved.