Haier HSU-09L03/H Operation Manual

Split type room air conditioner
SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-09L03/H
HSU-09R03/H
HSU-12L03/H
HSU-12R03/H
Please read this operation manual before using the air conditioner.
No.0010552593
Table of Contents
loading

Summary of Contents for Haier HSU-09L03/H

  • Page 1: Operation Manual

    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-09L03/H HSU-09R03/H HSU-12L03/H HSU-12R03/H Please read this operation manual before using the air conditioner. No.0010552593...
  • Page 2: Table Of Contents

    Contents Cautions Parts and functions Operation Maintenance Trouble shooting 4-111 12-14...
  • Page 3: Cautions

    Cautions The machine is adaptive in following situation I. Applicable ambient temperature range: Indoor Cooling Outdoor Indoor Heating Outdoor 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F 3.
  • Page 4: Parts And Functions

    Parts and Functions Indoor Unit Display board Display board Inlet Anion (inside) Vertical flap (Use remote controller to adjust up and down air flow. Don't adjust it manually) Horizontal louver (adjust left and right air flow) Outdoor Unit OUTLET INLET TIMER SIGNAL RECEIVING WINDOW OPERATE...
  • Page 5 Parts and Functions Operation ON/OFF TEMP MODE SWING SLEEP LOCK 25. RESET Used to reset the controller back to normal condition. 26. HEALTH Used to set healthy operation Clock set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM"...
  • Page 6: Operation

    When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFF to turn off the unit when power resumes.
  • Page 7 Operation Auto run, Fan operation (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL...
  • Page 8: Cool,Heat And Dry Operation

    Operation COOL,HEAT and DRY operation Recommendations: (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL...
  • Page 9 Operation (5) Air flow direction adjustment After operation mode is selected, vertical flap will open automatically according to the mode. Referring to the Fig. COOL About 10 Up and down (Use remote controller) Press SWING button, vertical flap will move within the range shown in the Fig.
  • Page 10: Timer Operation

    Operation TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode.
  • Page 11 Operation TIMER ON-OFF TIMER ON-OFF (1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2) Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: TIMER ON TIMER OFF Select TIMER ON-OFF.
  • Page 12: Emergency Operation

    Operation Emergency operation and test operation Emergency operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.
  • Page 13 Operation Comfortable SLEEP Before going to bed at night, you can simply press the SLEEP button and unit will bring you a sound sleep in selected mode. In COOL mode One hour after SLEEP mode starts, temp. will become 1 C higher than temp.
  • Page 14: Maintenance

    Close the inlet grille. Indoor Body Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
  • Page 15: Replacement Of Air Purifying Filter

    Maintenance Replacement of Air Purifying Filter 1.Open the lnlet Grille Open the inlet grille by pushing each ends of the inlet grille upward.(use thumbs to push 2.Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 3.Attach new Air Purifying Filter Put air purifying filter appliances into the right and left filter frames .
  • Page 16 Maintenance Better use of air conditioner Proper room temperature. Closing of doors and windows during operation Never fail to observe the followings Do not sprinkle water over the unit. Do not pull power plug. Cleaning of the air filter. Proper temperature Effective use of the timer.
  • Page 17: Trouble Shooting

    When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable.